TROUBLESHOOTING (VX600ER/VT600)
1. Connect:
Pocket tester
(to the battery terminals)
2. Measure:
Battery voltage
Fluid gravity
Battery voltage:
more than 12 V at 20
3. Start the engine and accelerate to 5,000
r/min.
4. Measure:
Charging voltage
Charging voltage:
14 V/5,000 r/min
WARNING
Be sure the V-belt is removed.
CAUTION:
Never disconnect battery cables while generator
is operating, otherwise, the rectifier/regulator will
be damaged.
Correct connector.
BATTERY IS NOT CHARGED.
°
°
C (68
F)
OK
SEA8350
OK
8-19
CHARGING SYSTEM
OUT OF SPECIFICATIONS
Check the battery.
Refer to "BATTERY INSPECTION" in CHAPTER 2.
Replace and/or charge the battery.
Refer to "BATTERY CHARGING" in CHAPTER 2.
OUT OF SPECIFICATION
Check the main fuse.
Refer to "FUSE INSPECTION" in CHAPTER 2.
Check the startor coil.
OK
Replace the main fuse and/or the startor
coil assembly.
Replace the rectifier/regulator.
+