Minimum Startup Configuration - Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual

Table of Contents

Advertisement

17.4

Minimum startup configuration

Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
1 CPU with CPU heat sink
1 memory module
Front panel module
1 Power supply module
Table 7: Minimum startup configuration - components
Cable
Front panel cable
Power cable
Table 8: Minimum startup configuration - cables
Ê Shut down the server as described in section
page
67.
Ê Remove the AC power cords from the PSU cable brackets and disconnect
them from the system as described in section
from the mains" on page
TX300 S7 / RX350 S7
Notes and reference
no TPM, UFM or expansion cards installed
installed in socket CPU 1, see section
"Installing processors" on page 551
installed in DIMM slot 1A, see section
"Memory sequence" on page 530
without connected front LAN module
installed in PSU slot 1, see section
PSU modules" on page 167
Notes and reference
see section
module" on page 700
see section
on page 179
68.
Upgrade and Maintenance Manual
"Replacing the front panel
"Replacing the power backplane"
"Shutting down the server" on
"Disconnecting the server
Appendix
"Installing
897