Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual page 898

Table of Contents

Advertisement

Appendix
Ê Take the system down to its minimum startup configuration.
Ê Reconnect the AC power cords to the power supply units and secure them
with PSU cable brackets as described in section
the mains" on page
Ê Connect a keyboard, mouse and display to the server.
Ê Switch on the server as described in section
page
131.
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
The minimum startup configuration must be used exclusively for
diagnostic purposes by maintenance personnel, never in daily
operation!
898
125.
Upgrade and Maintenance Manual
"Connecting the server to
"Switching on the server" on
TX300 S7 / RX350 S7