Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual page 888

Table of Contents

Advertisement

Appendix
Ê Remove the air duct as described in section
on page
92.
Ê Press the Indicate CSS button (1) to highlight defective components.
Component LEDs
I
LEDs A, B and C are visible from the outside on the server rear. All other
LEDs are only visible if the server cover has been opened.
Indicator
A
ID indicator
CSS
B
(Customer Self
Service)
GEL
C
(Global Error
LED)
D
PCI card
E
CPUs
F
Memory
G
PSUs
H
888
Status
Description
server has been highlighted using
ServerView Operations Manager or the
blue on
ID button on the front panel for easy
identification
off
no critical event (CSS component)
yellow on
prefailure detected (CSS component)
yellow
CSS component failure
flashing
off
no critical event (non CSS component)
prefailure detected (non CSS
orange on
component)
non CSS component failure
Possible reasons:
orange
– sensors report overheating
flashing
– sensor is defective
– CPU error
– software reports an error
off
PCI card operational
orange on
PCI card failure
off
CPUs operational
orange on
CPU failure
off
memory module operational
orange on
memory module failure
green on
PSUs operational
orange on
PSU failure
Upgrade and Maintenance Manual
"Removing the system air duct"
TX300 S7 / RX350 S7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primergy tx350 s7

Table of Contents