Figure 62. Locking Fixed Power Supply Into Chassis - Intel SC5650-DP Service Manual

Server chassis
Hide thumbs Also See for SC5650-DP:
Table of Contents

Advertisement

Hardware Installations and Upgrades
8. Rotate the blue locking mechanism to the locked position (see letter "A" in the
following figure).

Figure 62. Locking Fixed Power Supply into Chassis

9. Route and connect the P1, P2, P3 and P4 (for DP/BRP/WS), P1 and P2 (for UP)cables
to the server board. Refer to the Intel
Guide that came with your Intel
10. Route the P5 and P6 cables (for WS) to the PCI Express* graphic cards.
11. Route the P9 and P10 (for DP/BRP/WS), P3 and P4 (for UP) cables to the 5.25-in.
removable media device bays and connect to installed devices.
12. Route the P11, P12, P13, and P14 (for DP/BRP/WS), P6-P8 and P10-P12 (for UP)
cables to the hard drive cage and connect power cables to installed devices.
13. Install the left side cover. For instructions, see
14. Reconnect all peripheral devices and the AC power cable to the server. Power up the
server.
50
®
Server Board Quick Start User's Guide or User
®
server board for appropriate power connections.
"Installing the Left Side
®
Intel
Chassis SC5650-DP/WS/BRP/UP Service Guide
A
TP01755
Cover".