Intel S7000FC4UR - Server System - 0 MB RAM Product Manual

Product guide
Hide thumbs Also See for S7000FC4UR - Server System - 0 MB RAM:
Table of Contents

Advertisement

®
Intel
Server System S7000FC4UR
Product Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products
Intel Order Number D93989-002

Advertisement

Table of Contents
loading

Summary of Contents for Intel S7000FC4UR - Server System - 0 MB RAM

  • Page 1 ® Intel Server System S7000FC4UR Product Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Intel Order Number D93989-002...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
  • Page 3: Safety Information

    Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit CD 2 and/or at http://support.intel.com/support/...
  • Page 4 Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. Intel® Server System S7000FC4UR Product Guide...
  • Page 5 Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel® Server System S7000FC4UR Product Guide...
  • Page 6 Intel® Server System S7000FC4UR Product Guide...
  • Page 7: Preface

    Preface About this Manual ® Thank you for purchasing and using the Intel Server System S7000FC4UR. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server chassis. This document provides a brief overview of...
  • Page 8: Additional Information And Software

    If you just received this Intel Server System S7000FC4UR Quick Start User's Guide in the product and need to install product box Accessories or other Intel Spares and Configuration Guide server products Hardware (peripheral Tested Hardware Operating Systems List boards, adapter cards) and...
  • Page 9: Table Of Contents

    Front Panel Board ................32 SAS Backplane Board ................33 Power Distribution Board ..............35 Server and Platform Management ..............35 Chapter 2: Starting Up and Shutting Down the Server ....37 Powering Up the Server ................37 Intel® Server System S7000FC4UR Product Guide...
  • Page 10 Installing and Removing PCI Express* Add-in Cards ........68 Removing a Hot-swap PCI Card, Operating System Interface .....69 Removing a Hot-swap PCI Card, Hardware Interface ......71 Installing a Hot-swap PCI Card .............72 Removing a Non-hot-swap PCI Card ...........74 Intel® Server System S7000FC4UR Product Guide...
  • Page 11 Installing the SAS Riser Board ............. 98 Removing the SAS Riser Board ............99 Installing and Removing the Intel® RAID Activation Key and RAID DIMM 101 Installing the Intel® RAID Activation Key and RAID DIMM ....101 Removing the Intel® RAID Activation Key and RAID DIMM ....102 Installing and Removing the Intel®...
  • Page 12 English ......................167 Server Safety Information ..............167 Safety Warnings and Cautions ............167 Intended Application Uses ..............168 Site Selection ..................168 Equipment Handling Practices ............169 Power and Electrical Warnings ............169 System Access Warnings ..............170 Rack Mount Warnings ................171 Intel® Server System S7000FC4UR Product Guide...
  • Page 13 Product Regulatory Compliance Markings ......... 198 Electromagnetic Compatibility Notices ............200 FCC Verification Statement (USA) ............. 200 Industry Canada (ICES-003) .............. 201 Europe (CE Declaration of Conformity) ..........201 VCCI (Japan) ..................201 Intel® Server System S7000FC4UR Product Guide xiii...
  • Page 14 Warranty Limitations and Exclusions ............208 Limitations of Liability ................208 How to Obtain Warranty Service ..............209 Telephone Support ................209 Returning a Defective Product ............209 Appendix G: Getting Help ..............211 World Wide Web ..................211 Telephone ....................211 Intel® Server System S7000FC4UR Product Guide...
  • Page 15 List of Figures ® Figure 1. Intel Server System S7000FC4UR ........... 1 Figure 2. Front Components ................4 Figure 3. Front Panel Controls and Indicators ........... 6 ® Figure 4. Intel Local Control Panel..............8 Figure 5. System Rear ..................12 Figure 6.
  • Page 16 Figure 59. Disconnecting SAS and SES Cables from SAS Riser Board ..100 Figure 60. Removing SAS Riser Board ............100 Figure 61. Installing the Intel® RAID Activation Key and DIMM..... 102 Figure 62. Removing the CD-ROM / DVD-ROM Drive Carrier from the Server 105 Figure 63.
  • Page 17 Table 9. POST Progress Codes and Messages ..........138 Table 10. POST Error Manager Messages and Handling ......142 Table 11. Beep Codes ................... 153 Table 12. Product Regulatory Compliance Markings ........198 Intel® Server System S7000FC4UR Product Guide xvii...
  • Page 18 ® xviii Intel Server System S7000FC4UR Product Guide...
  • Page 19: Chapter 1: System Description

    The Intel Server System S7000FC4UR is a compact, high-density, 4U rack-mount ® ® system with support for one to four Intel Xeon processors MP and 256 GB of DDR2 533 MHz / 667 MHz FBDIMM memory. The system supports: •...
  • Page 20: System Features

    Rear access to hot-swap power supplies System power and system status LEDs System ID buttons and LEDs on front panel and rear of system Memory status LEDs Processor failure LEDs Color-coded parts to identify hot-swap and non-hot-swap serviceable components Intel® Server System S7000FC4UR Product Guide...
  • Page 21 System reset button NMI button System ID button and LED ® Optional Intel Local Control Panel System status LED Hard drive status LED LAN1 and LAN2 status LEDs Video connector Three USB 2.0 ports Intel® Server System S7000FC4UR Product Guide...
  • Page 22: System Front

    Description CD-ROM / DVD-ROM drive bay 5 ¼-inch peripheral bay Video connector USB 2.0 ports Front control panel. Standard control panel shown. Hot-swap fan modules (2) Hot-swap hard drives (8) Figure 2. Front Components Intel® Server System S7000FC4UR Product Guide...
  • Page 23: Front Control Panel

    Front Control Panel ® You can choose between the standard control panel or the Intel Local Control Panel to monitor and control your system locally. The standard control panel provides the following user interface for system management and status LEDs.
  • Page 24: Figure 3. Front Panel Controls And Indicators

    Press to reset the system System power button Press to turn the system power on or off System ID button Press to turn the system ID LED on or off Figure 3. Front Panel Controls and Indicators Intel® Server System S7000FC4UR Product Guide...
  • Page 25 Blue LED to identify the system through server management software System power Green LED to show system status LED State System Power State ACPI Power off Power on S4 / S5 Blink System power Toggles system power on and off button Intel® Server System S7000FC4UR Product Guide...
  • Page 26: Figure 4. Intel Local Control Panel

    Predictive hard drive / slot failure or rebuild in blink (~1 Hz) process Amber fast Rebuild interrupted or rebuild on empty slot blink (~2.5 System reset Resets the system button ® Figure 4. Intel Local Control Panel Intel® Server System S7000FC4UR Product Guide...
  • Page 27: Table 3. System Status Led States

    • PCI Express uncorrectable link errors • Critical threshold crossed (temperature, PROCHOT) • VRD hot-asserted • Minimum number of fans not present or too many fans failed Intel® Server System S7000FC4UR Product Guide...
  • Page 28: System Rear

    • No power good / power fault • Power unit redundancy sensor. Insufficient resources offset. Not enough power supplies present System Rear This diagram shows the system with the optional I/O panel installed. AF002231 Intel® Server System S7000FC4UR Product Guide...
  • Page 29 LAN Port LED LAN Status Status LED (green) Off: No Ethernet connected On: Ethernet link detected Blink: Ethernet link active Speed LED (green / amber) Off: 10 Mbps Green: 100 Mbps Amber: 1000 Mbps Intel® Server System S7000FC4UR Product Guide...
  • Page 30: Processors

    Memory board baffles are not needed for empty memory board slots, but DIMM blanks are required for each socket on each memory board in which a DIMM is not installed. Intel® Server System S7000FC4UR Product Guide...
  • Page 31: Figure 6. Memory Boards

    Supports Closed Loop Thermal Throttling with FBDIMM AMB temperature sensors • LED fault indicators for each DIMM • One field replaceable unit (FRU) EEPROM • Supports memory mirroring and memory sparing “Memory Board” on page 28 for additional information. Intel® Server System S7000FC4UR Product Guide...
  • Page 32: Power Subsystem

    AC inlets. In an N+1 configuration, the 12 VDC outputs have active (forced) current-sharing. The two externally enabled outputs have these maximum ratings: • +12 VDC: 121 A • +3.3 VDCSB: 5 A Intel® Server System S7000FC4UR Product Guide...
  • Page 33: Figure 7. Power Supply Indicators

    AC OK LED (green) This green LED is driven by internal circuitry and is lit whenever the AC power cord is plugged in to an active AC power source. Figure 7. Power Supply Indicators Intel® Server System S7000FC4UR Product Guide...
  • Page 34: Power Supply Consumption

    AC power circuit capability is not exceeded. When a server is connected to low-line power, the J6F1 jumper sets these power consumption thresholds: • Pins 1-2 covered: Sets the power consumption threshold to 1180 watts Intel® Server System S7000FC4UR Product Guide...
  • Page 35 If the jumper is covering pins 2-3 on a 115 / 120 / 127 VAC circuit, the server power consumption threshold is set to 1030 watts. The lower power threshold may be exceeded, limiting system performance. Intel® Server System S7000FC4UR Product Guide...
  • Page 36: Cooling Subsystem

    Each rear fan has one status LED. The LED is off when the fan is operating normally and illuminates amber if the fan fails. Failed rear fans can be replaced from the top of the system when the top cover is removed. AF002242 Figure 9. Rear Fan Locations Intel® Server System S7000FC4UR Product Guide...
  • Page 37: Hot-Swap Pci Slots

    Attention: Power fault or operational problem has occurred with this slot. Blinking Locate: The slot is being identified. Note: If you hot-remove a PCI card without following the proper procedure, power is automatically be turned off to the slot. Intel® Server System S7000FC4UR Product Guide...
  • Page 38: Peripherals

    Up to eight hot-swap 2.5-inch SAS hard drives or four 2.5-inch SATA hard drives • One 1/2-inch IDE DVD-ROM / CD-ROM drive • One 5 1/4-inch device bay AF002272 Item Description DVD-ROM / CD-ROM drive Tape drive (optional) Hard drives (eight) Figure 10. Peripheral Area Intel® Server System S7000FC4UR Product Guide...
  • Page 39: Hot-Swap Hard Drive

    Amber slow blink (~1 Hz) Predictive hard drive / slot failure or rebuild is in process Amber fast blink (~2.5 Hz) Hard drive rebuild interrupted or rebuild on empty slot Figure 11. Hard Drive Carrier Intel® Server System S7000FC4UR Product Guide...
  • Page 40: Optical Drive Bay

    The board set consists of these boards: • Main board • Memory boards • I/O riser board (optional) • SAS riser board (optional) • Front panel board • SAS backplane board • Power distribution board • SATA-to-IDE adapter board Intel® Server System S7000FC4UR Product Guide...
  • Page 41: Main Board

    Figure 13. Block Diagram Main Board The main board contains: • Chipset north and south bridge components • Processor sockets • Four memory board connectors • Video components • Trusted Platform Module • BIOS Flash components Intel® Server System S7000FC4UR Product Guide...
  • Page 42: Figure 14. Main Board Component Locations

    Figure 14. Main Board Component Locations Item Description Item Description Dual Ethernet ports Front panel connector I/O riser slot Power distribution board connectors PCI Express* x4 (slot 7) Processor socket 1 Serial Port A Processor socket 2 Intel® Server System S7000FC4UR Product Guide...
  • Page 43 Serial port B Memory board (slot C) Video port Single port SATA connectors USB 1 (top), USB 2 (bottom) Memory board (slot D) Memory board (slot A) Real-time clock battery Memory board (slot B) Intel® Server System S7000FC4UR Product Guide...
  • Page 44 1 - 2 = Disable BMC force update Empty 2 - 3 = Enable BMC force update BMC flash write protect J6D1 Stuff 1 - 2 = Disable flash write protect Empty 2 - 3 = Enable flash write protect Intel® Server System S7000FC4UR Product Guide...
  • Page 45: Figure 15. Main Board Jumpers

    • SATA4 to x4 connector Port3 goes to SATA Drive 3 on the SAS backplane board • SATA5 to SATA connector2 is an extra port that could be used for a SATA tape drive Intel® Server System S7000FC4UR Product Guide...
  • Page 46: Memory Board

    Dual DAC for simultaneous port support (front / rear video support) • Resolutions from VGA up to UXGA (1600 x 1200) ® • Digital Video Input/Output (DVI/DVO) interface routed to the Intel Remote ® Management Module 2 (Intel RMM) for KVM support up to 165 MHZ •...
  • Page 47: Figure 16. Memory Board Leds And Connectors

    DIMM8 Fault LED (amber). DIMM8 had an error and needs to be replaced DIMM1 Socket DIMM2 Socket DIMM3 Socket DIMM4 Socket DIMM5 Socket DIMM6 Socket DIMM7 Socket DIMM8 Socket Figure 16. Memory Board LEDs and Connectors Intel® Server System S7000FC4UR Product Guide...
  • Page 48: I/O Riser Board (Optional)

    RMM2 supports keyboard, mouse, video redirect, and media redirect functionality, which lets the user use the remote system to control the host server. The Intel 82575EB PCI Express*-based Ethernet controller provides advanced networking control and capability with dual-gigabit Ethernet ports. This controller hosts ®...
  • Page 49: Sas Riser Board (Optional)

    RAID Activation Key and DDR2-667 registered DIMM are ® installed, hardware RAID levels 0, 1, 5, 6, 10, 50, and 60 are enabled. The optional Intel RAID smart battery can be installed to provide DDR2 DIMM refresh support during a power failure.
  • Page 50: Front Panel Board

    Front Panel Board The front panel board provides access to the system video and USB interfaces. It also ® interfaces to the Standard Control Panel or Intel Local Control Panel module. The control modules contain the front panel buttons and LEDs.
  • Page 51: Sas Backplane Board

    Provides power and control for front system fans • Provides power to DVD/CD-ROM device and tape device Note: Because hard drives have different cooling, power, and vibration characteristics, Intel ® validates specific hard drive types. See the Intel Server System S7000FC4UR Tested Hardware and Operating System List for a list of supported drives.
  • Page 52: Figure 20. Sas Backplane Connectors (Interior Side)

    Power cable connector to CD-ROM / DVD-ROM drive and 5 ¼-inch peripheral Hot-swap cooling fan connector SAS x4 port B Power distribution board connector SAS x4 port A Front panel board connector Figure 20. SAS Backplane Connectors (Interior Side) AF002226 Intel® Server System S7000FC4UR Product Guide...
  • Page 53: Power Distribution Board

    • Interconnects • Server management controllers • Firmware algorithms • System BIOS The platform management system includes: • Baseboard management controller (BMC) • Watchdog timer • Messaging support, including command bridging and user/session support Intel® Server System S7000FC4UR Product Guide...
  • Page 54 LAN interface that supports the IPMI-over-LAN protocol (RMCP, RMCP+) • Serial-over-LAN (SOL) • Chassis intrusion detection and chassis intrusion cable presence detection ® • Support for the Intel Remote Management Module 2 • Platform environment control interface (PECI) thermal management support Intel® Server System S7000FC4UR Product Guide...
  • Page 55: Chapter 2: Starting Up And Shutting Down The Server

    Starting Up and Shutting Down the Server Powering Up the Server Press the power button on the front control panel. The fans start and POST begins. Note: It might take three minutes or longer for video to be displayed, depending on the amount of memory installed.
  • Page 56 Intel® Server System S7000FC4UR Product Guide...
  • Page 57: Chapter 3: Intel Server Deployment Toolkit

    Documentation, such as the Intel Server System S7000FC4UR Product Guide (this document), and other user guide documents • Adobe* Acrobat Reader Booting the CD starts the Intel Deployment Assistant utility. Alternatively, the drivers, utilities, and documentation content can be accessed through an HTML interface.
  • Page 58 Intel® Server System S7000FC4UR Product Guide...
  • Page 59: Chapter 4: Server Utilities

    Server Utilities Using the BIOS Setup Utility The BIOS Setup Utility is a text-based utility that allows you to configure the system and view and change device settings and view environmental information for the system. The interface consists of several screens, called pages, each of which contains information or links to other pages.
  • Page 60: Table 5. Setup Menu Key Use

    If <N> followed by <Enter> pressed, or if <Esc> is pressed, the user is returned to where they were before <F9> was pressed without affecting any field values. Intel® Server System S7000FC4UR Product Guide...
  • Page 61: System Configuration Reset

    — Move the NVRAM Clear jumper to default/normal mode (connect pins 1 and 2). — Power on the system. ® Note: Intel Server System S7000FC4UR does not support any other mechanisms to clear NVRAM. Intel® Server System S7000FC4UR Product Guide...
  • Page 62 1 - 2 = Disable flash write protect Empty 2 - 3 = Enable flash write protect Circuit breaker J6F1 Empty 1 - 2 = 20A/110V (USA) Stuff 2 - 3 = 15A/100V (Japan) Intel® Server System S7000FC4UR Product Guide...
  • Page 63: Rolling Bios

    Secondary Flash Bank. The BIOS flash update process works like this: 1. Boot the system. ® 2. Use the EFI Flash or the Intel One Flash Update (OFU) utility to update the BIOS. 3. Reset the system. 4. The rolling BIOS automatically: —...
  • Page 64: Console Redirection

    The BIOS supports multiple consoles, some of which are in graphics mode and some in text mode. The graphics consoles can display the logo while the text consoles receive the redirected text. Console redirection ends at the beginning of the Legacy OS boot (INT 19h). Intel® Server System S7000FC4UR Product Guide...
  • Page 65: Keystroke Mappings

    1 = VT100 (not implemented, but honored as VT100+) 2 = VT100+ 3 = VT-UTF8 <Esc>-CDZ0 Inhibit console redirection <Esc>-CDZ1 Restart console redirection <Esc>-CDZ2 “Soft” inhibit console redirection without serial port or modem reset Intel® Server System S7000FC4UR Product Guide...
  • Page 66: Limitations

    1. Boot the console into the operating system. 2. Click “Start” in the task bar. 3. Select Programs > Accessories > Communications. Click “Hyperterminal”. 4. At the Connection Description window, enter “guest” for the name and click “OK”. Intel® Server System S7000FC4UR Product Guide...
  • Page 67: Platform Confidence Test

    Platform Confidence Test ® The Platform Confidence Test (PCT) diagnostic utility is included on the Intel Server System S7000FC4UR Server Deployment Toolkit CD. It probes for the hardware at the start of each test and reports the identified components. In this way, the PCT indirectly identifies many assembly and cabling errors (broken or improperly seated cables) when installed components are not reported.
  • Page 68: Running The Platform Confidence Test

    Server System S7000FC4UR to be tested. Boot the system. 6. Press <F2> when prompted to enter the BIOS Setup utility. 7. From the BIOS Setup utility, go to the Boot Manager menu and choose “EFI Shell.” Intel® Server System S7000FC4UR Product Guide...
  • Page 69: Intel® Deployment Assistant

    Deployment Assistant provides a single interface with an easy to use HTML- like graphical user interface to ease the process of setting up and deploying an Intel server from initial boot through the initiation of an unattended OS installation. These setup and ®...
  • Page 70: Save And Restore System Configuration (Syscfg)

    Display selected firmware settings. • Display selected BIOS settings. FWPIAUPD Firmware Load Utility The Firmware Update utility updates these server management controllers: • Baseboard management controller (BMC) • Hot-swap controller (HSC) • LCD control panel (LCP) Intel® Server System S7000FC4UR Product Guide...
  • Page 71: One-Boot Flash Update Utility (Ofu)

    Generically handle FRU devices that might not be associated with the BMC. • Supply command lines and interactive input through the standard input device. • View and direct results to the standard output device. Intel® Server System S7000FC4UR Product Guide...
  • Page 72: Extensible Firmware Interface (Efi) Shell

    The EFI shell provides a set of basic commands to manage files and EFI NVRAM shell and boot variables. A list of these basic commands is in Table 7. Extensive information is available on the EFI website at http://developer.intel.com/ technology/efi: •...
  • Page 73 [-c] [-t] [-i[UGA Displays a bitmap file on the screen Instance]] file loadpcirom romfile Loads a PCI option ROM ls [-b] [dir] [dir] ... Obtains directory listings map [-bdvr] [sname[:]] Maps sname to device path [handle] Intel® Server System S7000FC4UR Product Guide...
  • Page 74 Delays for the specified number of microseconds time [hh:mm:ss] Gets or sets the time type [-a] [-u] [-b] file Displays the contents of a file Displays version information vol fs [volume_label] Sets or displays a volume label Intel® Server System S7000FC4UR Product Guide...
  • Page 75: Chapter 5: User-Serviceable Components

    User-Serviceable Components Note: This chapter provides instructions for adding and replacing hot-swappable and user- serviceable system components and memory DIMMs. A service technician is not required to perform the procedures described in this chapter. Before You Begin Before working with your server product, pay close attention to the “Safety Information”...
  • Page 76: Removing The Top Cover

    3. Unscrew the two captive screws on the faceplate. See letter “A” in the figure below. 4. Slide the top cover toward the rear until it stops, then lift the cover to remove it. See letter “B” in the figure. AF002233 Figure 22. Removing the Chassis Cover Intel® Server System S7000FC4UR Product Guide...
  • Page 77: Installing The Top Cover

    Cautions: • System cooling is reduced during the fan replacement process. Do not leave a system fan removed for longer than two minutes. • Do not touch the fan blades while they are turning. Intel® Server System S7000FC4UR Product Guide...
  • Page 78: Hot-Swapping A Rear System Fan

    Four cooling fans are located at the rear of the chassis. The top cover must be removed before these fans can be serviced. You can replace a failed cooling fan assembly without turning off the power to the server only if the remaining system fans are fully functional. Intel® Server System S7000FC4UR Product Guide...
  • Page 79: Figure 26. Removing A Rear System Fan

    3. Lift the fan upward. See the following figure. AF002244 Figure 26. Removing a Rear System Fan 4. Lower the replacement fan into the fan bay. 5. Push down on the fan until it clicks into place. Intel® Server System S7000FC4UR Product Guide...
  • Page 80: Hot-Swapping A Hard Drive

    Amber slow blink (~1 Hz) Predictive hard drive / slot failure or rebuild is in process Amber fast blink (~2.5 Hz) Hard drive rebuild interrupted or rebuild on empty slot Figure 27. Hard Drive Carrier Intel® Server System S7000FC4UR Product Guide...
  • Page 81: Removing A Hard Drive Carrier

    3. Set any jumpers and/or switches on the drive according to the drive manufacturer's instructions. 4. If the drive carrier is installed in the chassis, remove it and place it on a clean static- free work surface. For instructions, see “Removing a Hard Drive Carrier” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 82: Figure 29. Removing The Air Baffle From The Hard Drive Carrier

    9. Align the holes in the drive to the holes in the drive carrier slide track and insert the screws that were attached to the air baffle. See letter “B” in the figure. Figure 30. Attaching the Hard Drive to the Carrier Intel® Server System S7000FC4UR Product Guide...
  • Page 83: Installing A Hard Drive Carrier

    2. Use the handle to push the carrier until it docks in the chassis, then close the drive carrier handle. See letter “B” in the figure. AF002265 Figure 31. Installing Hard Drive into Server Intel® Server System S7000FC4UR Product Guide...
  • Page 84: Hot-Swapping A Power Supply

    Because of chassis airflow disruption, a power supply bay should never be vacant for more than two minutes when the server power is on. Exceeding five-minutes might cause the system to exceed the maximum acceptable temperature and possibly damage system components. Intel® Server System S7000FC4UR Product Guide...
  • Page 85: Figure 33. Removing A Power Supply

    See letter “A” in the following figure. 9. Rotate the handle to the closed position until it clicks and is latched in place. See letter “B” in the figure. Intel® Server System S7000FC4UR Product Guide...
  • Page 86: Installing And Removing Pci Express* Add-In Cards

    1 and 2 are at the right. Caution: Expansion slot covers must be installed over all vacant slots to maintain the electromagnetic emission characteristics of the server and to ensure proper system cooling. Intel® Server System S7000FC4UR Product Guide...
  • Page 87: Removing A Hot-Swap Pci Card, Operating System Interface

    “A” in the following figure. 7. If a full-length card is installed, press the blue plastic piece at the front of the card. 8. Pull up on the card to remove it. See letter “B” in the figure. Intel® Server System S7000FC4UR Product Guide...
  • Page 88: Figure 35. Removing A Pci Card

    — To install a replacement PCI card: see “Installing a Hot-swap PCI Card” on page 11. Install the top cover. For instructions, see “Installing the Top Cover” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 89: Removing A Hot-Swap Pci Card, Hardware Interface

    6. If a full-length card is installed, press the blue plastic piece at the front of the card. 7. Pull up on the card to remove it. 8. Store the card in an anti-static bag. 9. Install an expansion slot cover over the empty slot or install a replacement PCI card: Intel® Server System S7000FC4UR Product Guide...
  • Page 90: Installing A Hot-Swap Pci Card

    7. Align and slide the adapter board down until it seats in its connector. If you are installing a full-length card, guide the front of the card into the slot shown by letter “D” in the figure. 8. Press the card down firmly until it seats into the slot. Intel® Server System S7000FC4UR Product Guide...
  • Page 91: Figure 37. Installing A Pci Add-In Card

    11. If using the operating system hot-plug interface: ✧ Wait for the software user interface to appear on your monitor and then confirm the device to be enabled. ✧ Wait for the power LED to turn on. Intel® Server System S7000FC4UR Product Guide...
  • Page 92: Removing A Non-Hot-Swap Pci Card

    See letter “C” in Figure 36. ✧ To install a replacement PCI card, see “Installing a Hot-swap PCI Card”, below. 7. Install the top cover. For instructions, see “Installing the Top Cover” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 93: Installing A Non-Hot-Swap Pci Card

    Two memory boards, installed in Slots A and B, the two boards at the right side of the system • All four memory boards, Slots A, B, C, and D AC power must be removed from the system before servicing the memory boards. Intel® Server System S7000FC4UR Product Guide...
  • Page 94: Removing A Memory Board

    See letters “A” and “B” in the following figure. AF002249 Figure 38. Opening Memory Board Latches 3. Lift the memory board by the latches to pull it from the server. Intel® Server System S7000FC4UR Product Guide...
  • Page 95: Figure 39. Removing A Memory Board

    AF002238 Figure 39. Removing a Memory Board Intel® Server System S7000FC4UR Product Guide...
  • Page 96: Installing A Memory Board

    3. Once the board is lowered as far as possible, rotate the latches downward to firmly engage the board into the memory board slot. 4. Install the top cover. For instructions, see “Installing the Top Cover” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 97: Installing And Removing Dimms

    For example, DIMMs A1 and B1 can be different from DIMMs A2 and B2. • Additional memory can be added by installing identical pairs of DIMMs in the lowest numbered available slots. Intel® Server System S7000FC4UR Product Guide...
  • Page 98: Figure 42. Memory Board A And B Population

    (numbers) across the two branches must be identical. For example, DIMMs A1 and B1 must be identical to DIMMs C1 and D1. • Additional memory can be added by installing identical pairs of DIMMs in the lowest numbered available slots. Intel® Server System S7000FC4UR Product Guide...
  • Page 99: Installing Dimms

    3. Press down on the hooks on the underside of the memory board to disengage them. See letter “A” in the following figure. 4. Lift the memory board DIMM cover from the memory board. Intel® Server System S7000FC4UR Product Guide...
  • Page 100: Figure 44. Remove Memory Board Dimm Cover

    8. Insert the bottom edge of the DIMM into the socket. 9. Push down on the top edge of the DIMM. The levers at each end of the DIMM socket will close. Make sure the levers close securely. Intel® Server System S7000FC4UR Product Guide...
  • Page 101: Figure 45. Install Dimms

    12. Press down on the cover until the hooks on both the top and bottom of the cover click into place around the memory board. 13. Install the memory board. For instructions, see “Installing a Memory Board” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 102: Removing Dimms

    Store it in an antistatic bag. 7. Install replacement DIMMs if necessary. For instructions, see “Installing DIMMs” on page 8. Install the memory board. For instructions, see “Installing a Memory Board” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 103: Chapter 6: Technician Maintenance

    Technician Maintenance Note: This chapter describes procedures that require internal server access. You must be a qualified service configuration technician to perform procedures listed in this chapter. To perform these procedures power down the server and remove all power cords from the server.
  • Page 104: Component Locations

    Processor socket 3 PCI Express x4 (slot 5) Processor socket 4 PCI Express x8 (slot 4) SAS riser slot PCI Express x8 (slot 3) Chassis intrusion PCI Express x8 hot-plug (slot 2) 4-port SATA connector Intel® Server System S7000FC4UR Product Guide...
  • Page 105: Figure 46. Main Board Component Locations

    Video port Single port SATA connectors USB 1 (top), USB 2 (bottom) Memory board (slot D) Memory board (slot A) Real-time clock battery Memory board (slot B) Figure 46. Main Board Component Locations AF002227 Intel® Server System S7000FC4UR Product Guide...
  • Page 106: Figure 47. Sas Backplane Connectors (Interior Side)

    Power cable connector to CD-ROM / DVD-ROM drive and 5 ¼-inch peripheral Hot-swap cooling fan connector SAS x4 port B Power distribution board connector SAS x4 port A Front panel board connector Figure 47. SAS Backplane Connectors (Interior Side) AF002226 Intel® Server System S7000FC4UR Product Guide...
  • Page 107: Figure 48. Sas Backplane Connectors (Drive Bay Side)

    Hard Drive 6 Hard Drive 7 Figure 48. SAS Backplane Connectors (Drive Bay Side) AF002262 Item Description Control panel connector Main board connector SAS backplane board connector Figure 49. Front Panel Board Component Locations Intel® Server System S7000FC4UR Product Guide...
  • Page 108: Removing And Installing The Top Cover

    3. Unscrew the two captive screws on the faceplate. See letter “A” in the figure below. 4. Slide the top cover toward the rear until it stops, then lift the cover to remove it. See letter “B” in the figure. Intel® Server System S7000FC4UR Product Guide...
  • Page 109: Installing The Top Cover

    3. Tighten the captive screws on the faceplate. Use a torque setting of 0.90 N M (8 in lb). See letter “B” in the figure. 4. Reconnect all peripheral devices and the AC power cord. 5. Slide the system back into the rack. Intel® Server System S7000FC4UR Product Guide...
  • Page 110: Removing And Installing The Processor Air Baffle

    6. Insert fingers into the holes on top of the air baffle. 7. Pull the baffle up and back to disengage the baffle from the two sheet metal tabs at the front of the baffle. Lift the baffle up to remove it. Intel® Server System S7000FC4UR Product Guide...
  • Page 111: Figure 52. Removing The Processor Air Baffle

    AF002236 Figure 52. Removing the Processor Air Baffle Intel® Server System S7000FC4UR Product Guide...
  • Page 112: Installing The Processor Air Baffle

    Slide the tabs on the baffle under the sheet metal at the front of the baffle. One tab is located on each side of the chassis. See letter “B” in the figure. AF002277 Figure 53. Installing the Processor Air Baffle Intel® Server System S7000FC4UR Product Guide...
  • Page 113: Figure 54. Engaging The Processor Air Baffle Guides

    4. Connect the 100-pin cable to the front panel I/O board. See letter “B” in Figure 49 on page 89 to locate the connection point. 5. Connect any necessary cables to the device in the 5 ¼-inch peripheral bay. Intel® Server System S7000FC4UR Product Guide...
  • Page 114: Removing And Installing The Lower Air Baffle

    2. Remove the processor air baffle. For instructions, see “Removing the Processor Air Baffle” on page 3. Pull up on the lower air baffle to remove it. AF002237 Figure 55. Removing the Lower Center Air Baffle Intel® Server System S7000FC4UR Product Guide...
  • Page 115: Installing The Lower Air Baffle

    AF002248 Figure 56. Installing the Lower Center Air Baffle Intel® Server System S7000FC4UR Product Guide...
  • Page 116: Installing And Removing The Sas Riser Board (Optional)

    The SAS riser board supports RAID levels 0, 1, 1a, and 10 without any additional ® components (Integrated RAID mode). With the addition of the Intel RAID Activation Key and a RAID DIMM, enhanced RAID capability and support for RAID levels 0, 1, 1a, 5, 6, 10, 50, and 60 are enabled.
  • Page 117: Removing The Sas Riser Board

    3. Remove the two SAS cables from the SAS riser board by pressing on the top of the cable connector and pulling the cable from the SAS port. See the following figure. 4. Remove the SES cable from the SAS riser board. Intel® Server System S7000FC4UR Product Guide...
  • Page 118: Figure 59. Disconnecting Sas And Ses Cables From Sas Riser Board

    Figure 59. Disconnecting SAS and SES Cables from SAS Riser Board 5. Push back the slot divider’s latch. While pushing back on the latch, pull up on the SAS riser board to remove it. AF002251 Figure 60. Removing SAS Riser Board Intel® Server System S7000FC4UR Product Guide...
  • Page 119: Installing And Removing The Intel® Raid Activation Key And Raid Dimm

    The DIMM must be a 256 MB or 512 MB DDR2-667 DIMM. Installing the Intel® RAID Activation Key and RAID DIMM 1. Remove the top cover. For instructions, see “Removing the Top Cover”...
  • Page 120: Removing The Intel® Raid Activation Key And Raid Dimm

    RAID AF002255 Figure 61. Installing the Intel® RAID Activation Key and DIMM 11. Install the SAS riser board. For instructions, see “Installing the SAS Riser Board” on page 12. Install the processor air baffle. For instructions, see “Installing the Processor Air Baffle”...
  • Page 121 “Installing the SAS Riser Board” on page 10. Install the processor air baffle. For instructions, see “Installing the Processor Air Baffle” on page 11. Install the top cover. For instructions, see “Installing the Top Cover” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 122: Installing And Removing The Intel® Raid Smart Battery Axxrsbbu4

    ® For installation instructions, see the Intel RAID Smart Battery AXXRSBBU4 User’s ® Guide that came with your Smart Battery kit or on your Intel Server Deployment Toolkit CD 2. Installing and Removing the CD-ROM / DVD-ROM Drive The server system accommodates one DVD-ROM / CD-ROM drive. The device is not hot-swappable, so the system must be powered down and the power cords removed from the chassis before installing or removing this drive.
  • Page 123: Figure 62. Removing The Cd-Rom / Dvd-Rom Drive Carrier From The Server

    6. Pull out on the SATA-to-IDE converter board to remove it. See letter “C” in the figure. Figure 63. Removing the CD-ROM / DVD-ROM Drive from the Carrier 7. Store the drive in an antistatic protective wrapper or in its original packaging. Intel® Server System S7000FC4UR Product Guide...
  • Page 124: Installing A Cd-Rom / Dvd-Rom Drive

    See letter “A” in the following figure. 8. Plug the SATA cable and power cable into the converter board. See letter “B” in the figure. 9. Install the top cover. For instructions, see “Installing the Top Cover” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 125: Installing And Removing A 5 ¼-Inch Peripheral Device

    Installing and Removing a 5 ¼-inch Peripheral Device The server system accommodates one 5 ¼-inch peripheral device. To install or remove this device, the system must be powered down and the power cords removed. Intel® Server System S7000FC4UR Product Guide...
  • Page 126: Installing A 5 ¼-Inch Peripheral Device

    7. Attach the Y-cable to the 5 ¼-inch peripheral. 8. Slide the 5 ¼-inch peripheral device into the server until it clicks into place. See the following figure. 9. Install the top cover. For instructions, see “Installing the Top Cover” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 127: Removing A 5 ¼-Inch Peripheral Device

    7. If installing a replacement device, attach the Y-power cable to the device. 8. Slide the device or filler panel into the 5 ¼ bay until it clicks into place. See Figure 67 on page 109. Intel® Server System S7000FC4UR Product Guide...
  • Page 128: Servicing The Processors

    Servicing the Processors ® ® The server system requires at least one Intel Xeon Processor 7300 Series or at least one ® ® Dual-Core Intel Xeon Processor 7200 Series. Follow these rules: • Each processor socket must include either a processor thermal blank, or a processor and heat sink combination.
  • Page 129: Installing And Removing A Processor Thermal Blank

    / or processor thermal blanks. ® Caution: Using a processor thermal blank that is not expressly designed for the Intel Server System S7000FC4UR is not supported and may result in processor thermal issues.
  • Page 130: Installing A Processor Thermal Blank

    Figure 69. Installing a Thermal Blank 6. Install the processor air baffle. For instructions, see “Installing the Processor Air Baffle” on page 7. Install the top cover. For instructions, see “Installing the Top Cover” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 131: Installing And Removing A Processor

    Caution: Failure to correctly apply thermal grease between a processor and the heat sink could cause damage to the server. ® Caution: Using a processor heat sink that is not expressly designed for the Intel Server System S7000FC4UR is not supported and may result in processor thermal issues.
  • Page 132: Figure 71. Set Processor Into Socket

    Do not fully tighten one screw at a time. 11. Install the processor air baffle. For instructions, see “Installing the Processor Air Baffle” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 133: Removing A Processor

    “Installing the Processor Air Baffle” on page 10. Install the top cover. For instructions, see “Installing the Top Cover” on page Note: Once the processor is removed, note that the release mechanism shows the socket is open. Intel® Server System S7000FC4UR Product Guide...
  • Page 134: Removing And Installing The Center Brace

    5. Slide the latches at each side of the chassis to the unlock position. See letter “A” in the following figure. 6. Lift the center brace from the system. See letter “B” in the figure. AF002280 Figure 74. Removing the Center Brace Intel® Server System S7000FC4UR Product Guide...
  • Page 135: Installing The Center Brace

    Installing the Center Brace Set the center brace into position in the chassis. When correctly positioned, the latches will snap closed. AF002279 Figure 75. Installing the Center Brace Intel® Server System S7000FC4UR Product Guide...
  • Page 136: Installing And Removing The I/O Riser Board

    4. Installed an expansion slot cover by sliding it down to cover the opening. 5. Press the card down firmly until it seats into the slot. 6. Install the top cover. For instructions, see “Installing the Top Cover” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 137: Installing And Removing The Intel ® Remote Management Module

    RMM2. Note: The I/O gasket is required to meet EMI requirements. ® 5. Peel the backing from the EMI gasket that is included with your Intel Remote Management Module 2 kit. See letter “A” in the following figure. 6. Adhere the EMI gasket to the I/O riser board where the NIC will contact the I/O riser.
  • Page 138: Figure 76. Attaching The Emi Gasket

    I n t e g r a t e d N e t w o r k I / O M o d u l R M M N I C AF002285 Figure 77. Installing the RMM2 NIC Intel® Server System S7000FC4UR Product Guide...
  • Page 139: Removing The Intel Rmm2 And Nic Module

    ® 8. Align the connector on the Intel RMM2 to the J6C1 connector on the I/O riser ® board and align the plastic standoff on the Intel RMM2 corresponding hole in the I/O riser board. ® 9. Push down on the Intel RMM2 to attach it to the I/O riser board.
  • Page 140: Replacing The Main Board

    A rivet is on each side of the divider assembly. Pull up on the two rivets. See letter “A” in the following figure. b. Lift the divider assembly from the server. See letter “B” in the figure. Intel® Server System S7000FC4UR Product Guide...
  • Page 141: Figure 79. Removing The Pci Dividers

    See letter “B” in the figure. 17. Use the plunger to lift the board from the chassis. See letter “C” in the figure. 18. Install a replacement main board. For instructions, see “Installing the Main Board” on page 124. Intel® Server System S7000FC4UR Product Guide...
  • Page 142: Installing The Main Board

    3. While holding the plunger, slide the board to the rear of the chassis, aligning the two slots at the rear of the board with the tabs in the chassis. See letter “C” in the figure. 4. Release the plunger and ensure it is fully seated. Intel® Server System S7000FC4UR Product Guide...
  • Page 143: Figure 81. Installing The Main Board

    Figure 81. Installing the Main Board 5. Install the PCI slot dividers by lining up the rivets in the divider base with the holes in the main board. Push down on the rivets. See the following figure. Intel® Server System S7000FC4UR Product Guide...
  • Page 144: Figure 82. Installing The Pci Slot Dividers

    11. Install the I/O riser board. For instructions, see “Installing the I/O Riser Board” on page 118. ® ® 12. Install the processors. See “Handling the Intel Xeon Processor MP” on page 110 and then “Installing a Processor” on page 113. Intel® Server System S7000FC4UR Product Guide...
  • Page 145: Replacing The Sas Backplane Board

    7. Pull the SAS backplane upward to remove it. 8. Store the SAS backplane in an anti-static bag. 9. Install the replacement SAS backplane. For instructions, see “Installing the SAS Backplane Board” on page 128. Intel® Server System S7000FC4UR Product Guide...
  • Page 146: Installing The Sas Backplane Board

    “Removing the Top Cover” on page 3. Remove the main board. For instructions, see “Removing the Main Board” on page 122. 4. Disconnect the power distribution cable from the SAS backplane. See letter “A” in the following figure. Intel® Server System S7000FC4UR Product Guide...
  • Page 147: Figure 83. Power Distribution Cable Location On Sas Backplane

    Figure 83. Power Distribution Cable Location on SAS Backplane 5. Remove the seven screws on the power distribution board. See letter “A” in the following figure. 6. Lift the board from the chassis. See letter “B” in the figure. Intel® Server System S7000FC4UR Product Guide...
  • Page 148: Installing The Power Distribution Board

    66. Follow steps 7 through 9 only. 6. Install the main board. For instructions, see “Installing the Main Board” on page 124. 7. Install the top cover. For instructions, see “Installing the Top Cover” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 149: Replacing The Front Panel Board

    5. Slide the board towards the rear of the chassis until the tabs disengage from the board. See letters “B” and “C” in the figure. 6. Lift the board from the chassis. See letter “D”. Intel® Server System S7000FC4UR Product Guide...
  • Page 150: Installing The Front Panel Board

    Figure 49 on page 5. Install the processor air baffle. For instructions, see “Installing the Processor Air Baffle” on page 6. Install the top cover. For instructions, see “Installing the Top Cover” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 151: Replacing The Cmos Battery

    Warning: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the equipment manufacturer. Discard used batteries according to manufacturer's instructions. Intel® Server System S7000FC4UR Product Guide...
  • Page 152 See the following figure. Caution: Do not attempt to pull the battery up until it is pushed clear of the smaller prongs. Doing so may damage the battery holder. Intel® Server System S7000FC4UR Product Guide...
  • Page 153: Figure 88. Removing The Battery

    10. If you needed to remove memory boards to access the battery, install them. For instructions, see “Installing a Memory Board” on page 11. Install the top cover. For instructions, see “Installing the Top Cover” on page Intel® Server System S7000FC4UR Product Guide...
  • Page 154 Intel® Server System S7000FC4UR Product Guide...
  • Page 155: Appendix A: Post Codes

    Appendix A: POST Codes The system BIOS displays error messages on the video screen. Before video initialization, beep codes inform you of errors. POST error codes are logged in the event log. The BIOS displays POST error codes on the video monitor. Eight light-emitting diodes indicate the raw binary output of port 80 values.
  • Page 156: Table 9. Post Progress Codes And Messages

    Optimizing memory controller settings 0x27 Initializing memory, such as ECC init 0x28 Testing memory PCI Bus 0x50 Enumerating PCI buses 0x51 Allocating resources to PCI buses 0x52 Hot Plug PCI controller initialization 0x53-0x57 Reserved for PCI Bus Intel® Server System S7000FC4UR Product Guide...
  • Page 157 Instructing keyboard controller to run self-test (PS2 only) Mouse (USB only) 0x98 Resetting the mouse 0x99 Detecting the mouse 0x9A Detecting the presence of mouse 0x9B Enabling the mouse Fixed Media 0xB0 Resetting fixed media device Intel® Server System S7000FC4UR Product Guide...
  • Page 158 Entering BIOS setup 0xEA Flash Update 0xEE Calling Int 19. One beep unless silent boot is enabled. 0xEF Unrecoverable boot failure Runtime Phase / EFI Operating System Boot 0xF4 Entering sleep state 0xF5 Exiting sleep state Intel® Server System S7000FC4UR Product Guide...
  • Page 159: Post Error Messages And Handling

    — The BIOS logs an error message to the BMC System Event Log (SEL). — The BIOS continues booting in a degraded state by default (i.e. BIOS does not automatically enter the POST Error Manager to display the error message). Intel® Server System S7000FC4UR Product Guide...
  • Page 160: Table 10. Post Error Manager Messages And Handling

    Processor voltage mismatch detected Fatal 5220 CMOS / NVRAM configuration cleared Major 5221 Passwords cleared by jumper Major 5224 Password clear jumper is set Major 8110 Processor 01 internal error (IERR) on last boot Major Intel® Server System S7000FC4UR Product Guide...
  • Page 161 Major 84F3 Baseboard management controller in update mode Major 84F4 Sensor data record empty Major 84FF System event log full Minor 8500 Memory component could not be configured in the Major selected RAS mode Intel® Server System S7000FC4UR Product Guide...
  • Page 162 DIMM_1. 8531 Memory failed Self Test (BIST). Memory Board C, Major DIMM_2. 8532 Memory failed Self Test (BIST). Memory Board C, Major DIMM_3. 8533 Memory failed Self Test (BIST). Memory Board C, Major DIMM_4. Intel® Server System S7000FC4UR Product Guide...
  • Page 163 Memory Board A, DIMM_8 Disabled Major 8548 Memory Board B, DIMM_1 Disabled Major 8549 Memory Board B, DIMM_2 Disabled Major 854A Memory Board B, DIMM_3 Disabled Major 854B Memory Board B, DIMM_4 Disabled Major Intel® Server System S7000FC4UR Product Guide...
  • Page 164 Serial Presence Detection (SPD) fail error 8564 Memory Board A, DIMM_5 Component encountered Major a Serial Presence Detection (SPD) fail error 8565 Memory Board A, DIMM_6 Component encountered Major a Serial Presence Detection (SPD) fail error Intel® Server System S7000FC4UR Product Guide...
  • Page 165 Serial Presence Detection (SPD) fail error 8578 Memory Board D, DIMM_1 Component encountered Major a Serial Presence Detection (SPD) fail error 8579 Memory Board D, DIMM_2 Component encountered Major a Serial Presence Detection (SPD) fail error Intel® Server System S7000FC4UR Product Guide...
  • Page 166 Memory Board B, DIMM_4 Correctable ECC error Minor, Major after encountered 858C Memory Board B, DIMM_5 Correctable ECC error Minor, Major after encountered 858D Memory Board B, DIMM_6 Correctable ECC error Minor, Major after encountered Intel® Server System S7000FC4UR Product Guide...
  • Page 167 Minor, Major after encountered 859F Memory Board D, DIMM_8 Correctable ECC error Minor, Major after encountered 85A0 Memory Board A, DIMM_1 Uncorrectable ECC error Major encountered 85A1 Memory Board A, DIMM_2 Uncorrectable ECC error Major encountered Intel® Server System S7000FC4UR Product Guide...
  • Page 168 Memory Board C, DIMM_3 Uncorrectable ECC error Major encountered 85B3 Memory Board C, DIMM_4 Uncorrectable ECC error Major encountered 85B4 Memory Board C, DIMM_5 Uncorrectable ECC error Major encountered 85B5 Memory Board C, DIMM_6 Uncorrectable ECC error Major encountered Intel® Server System S7000FC4UR Product Guide...
  • Page 169 Keyboard component was not detected Minor 9226 Keyboard component encountered a controller error Minor 9243 Mouse component was not detected Minor 9246 Mouse component encountered a controller error Minor 9266 Local Console component encountered a controller Minor error Intel® Server System S7000FC4UR Product Guide...
  • Page 170 96A7 DXE boot services driver component encountered a Fatal illegal software state error 96AB DXE boot services driver component encountered Minor invalid configuration 96E7 SMM driver component encountered a illegal Fatal software state error Intel® Server System S7000FC4UR Product Guide...
  • Page 171: Post Error Beep Codes

    BIOS rolling back error The system has detected a corrupted BIOS in the flash part, and is rolling back to the last good BIOS. 1-5-2-1 CPU: Empty slot / population error. Intel® Server System S7000FC4UR Product Guide...
  • Page 172 Table 11. Beep Codes Beeps Error Message Description 1-5-4-2 Power fault: DC power unexpectedly lost (power good dropout) 1-5-4-4 Power control fault (Power good assertion timeout) Intel® Server System S7000FC4UR Product Guide...
  • Page 173: Appendix B: Installation / Assembly Safety Instructions

    Appendix B: Installation / Assembly Safety Instructions English The power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel. Do not attempt to modify or use the supplied AC power cord if it is not the exact type required. A product with more than one power supply will have a separate AC power cord for each supply.
  • Page 174 • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. ® Intel Server System S7000FC4UR Product Guide...
  • Page 175: Deutsch

    Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. ® Intel Server System S7000FC4UR Product Guide...
  • Page 176 Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. ® Intel Server System S7000FC4UR Product Guide...
  • Page 177: Français

    Notez que le commutateur CC de mise sous tension /hors tension du panneau avant n'éteint pas l'alimentation CA du système. Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. ® Intel Server System S7000FC4UR Product Guide...
  • Page 178 Danger d'explosion si la batterie n'est pas remontée correctement. Remplacer uniquement avec une batterie du même type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. ® Intel Server System S7000FC4UR Product Guide...
  • Page 179: Español

    Nótese que el interruptor activado / desactivado en el panel frontal no desconecta la corriente alterna del sistema. Para desconectarla, deberá desenchufar todos los cables de corriente alterna de la pared o desconectar la fuente de alimentación. ® Intel Server System S7000FC4UR Product Guide...
  • Page 180 También conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes. Por ello, se recomienda precaución y el uso de guantes protectores. ® Intel Server System S7000FC4UR Product Guide...
  • Page 181: Italiano

    Non modificare o utilizzare il cavo di alimentazione in c.a. fornito dal produttore, se non corrisponde esattamente al tipo richiesto. Ad ogni fonte di alimentazione corrisponde un cavo di alimentazione in c.a. separato ® Intel Server System S7000FC4UR Product Guide...
  • Page 182 Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. ® Intel Server System S7000FC4UR Product Guide...
  • Page 183 • Dotata di una presa a muro correttamente installata. • Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System S7000FC4UR Product Guide...
  • Page 184 ® Intel Server System S7000FC4UR Product Guide...
  • Page 185: Appendix C: Safety Information

    To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel server product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
  • Page 186: Intended Application Uses

    • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. ® Intel Server System S7000FC4UR Product Guide...
  • Page 187: Equipment Handling Practices

    Do not attempt to modify or use an AC power cord if it is not the exact type required. A separate AC cord is required for each system power supply. ® Some power supplies in Intel servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.
  • Page 188: System Access Warnings

    Caution: To avoid injury do not contact moving fan blades. If your system is supplied with a guard over the fan, do not operate the system without the fan guard in place. ® Intel Server System S7000FC4UR Product Guide...
  • Page 189: Rack Mount Warnings

    -- on your server when handling parts. Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, ® Intel Server System S7000FC4UR Product Guide...
  • Page 190: Other Hazards

    Dispose of batteries according to local ordinances and regulations. Do not attempt to recharge a battery. Do not attempt to disassemble, puncture, or otherwise damage a battery. ® Intel Server System S7000FC4UR Product Guide...
  • Page 191: Cooling And Airflow

    Caution: To avoid risk of radiation exposure and / or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing ® Intel Server System S7000FC4UR Product Guide...
  • Page 192: Sicherheitshinweise Für Den Server

    Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, ®...
  • Page 193: Zielbenutzer Der Anwendung

    Telekommunikationskabel zum Modem abziehen. • Eine ordnungsgemäß geerdete Wandsteckdose muß vorhanden sein. • Ausreichender Freiraum für den Zugang zu den Netzkabeln, da diese die Hauptvorrichtung zum Trennen des Produkts von der Stromversorgung sind. ® Intel Server System S7000FC4UR Product Guide...
  • Page 194: Handhabung Von Geräten

    Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 195: Warnhinweise Für Den Systemzugang

    Vorsicht: War Ihr Server in Betrieb, können die installierten Prozessoren und Kühlkörper heiß sein. Sofern Sie keine Hot-Plug-Komponenten ein- oder ausbauen, warten Sie mit dem Abnehmen der Abdeckungen, bis das System abgekühlt ist. Gehen Sie beim Aus- oder ® Intel Server System S7000FC4UR Product Guide...
  • Page 196: Warnhinweise Für Racks

    Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. ® Intel Server System S7000FC4UR Product Guide...
  • Page 197: Andere Gefahren

    • Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. ® Intel Server System S7000FC4UR Product Guide...
  • Page 198: Français

    Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
  • Page 199: Domaines D'utilisation Prévus

    • Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. ® Intel Server System S7000FC4UR Product Guide...
  • Page 200: Alimentation Et Avertissements En Matière D'électricité

    Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle / neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 201: Avertissements Sur L'accès Au Système

    Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. ® Intel Server System S7000FC4UR Product Guide...
  • Page 202: Avertissements Sur Le Montage En Rack

    ESD. Ne tenez les cartes que par leurs bords. Après avoir retiré une carte de son emballage de protection ou du serveur, placez-la sur une surface reliée à la terre, exempte de charge statique, composants orientés vers le haut. Utilisez si possible un tapi de ® Intel Server System S7000FC4UR Product Guide...
  • Page 203: Autres Risques

    Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. ® Intel Server System S7000FC4UR Product Guide...
  • Page 204: Información De Seguridad Del Servidor

    Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , las carcasas de servidor de ® Intel (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o...
  • Page 205: Aplicaciones Y Usos Previstos

    Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. ® Intel Server System S7000FC4UR Product Guide...
  • Page 206: Advertencias De Alimentación Y Eléctricas

    CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
  • Page 207: Advertencias El Acceso Al Sistema

    Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. ® Intel Server System S7000FC4UR Product Guide...
  • Page 208: Advertencias Sobre El Montaje En Bastidor

    Sujételas sólo por los bordes. Una vez extraída la tarjeta de su envoltorio de protección o del servidor, colóquela con el lado de los componentes hacia arriba sobre una superficie con toma de tiearra y sin carga estática. Utilice una ® Intel Server System S7000FC4UR Product Guide...
  • Page 209 Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. ® Intel Server System S7000FC4UR Product Guide...
  • Page 210 简体中文 服务器安全信息 本文档适用于 Intel® 服务器主板、Intel® 服务器机箱(基座和机架固定件)和已安装的外设。为减少人身伤害、电击、火 以及设备毁坏的危险,请在安装或维护 Intel® 服务器产品之前阅读本文档并遵循本指南中的所有警告和预防措施。 如果本文档中的信息与特定产品的随附信息或 Web 站点信息之间存在不一致,请以产品文档为准。 服务器须由合格的技术人员进行集成和维护。 必须遵守本指南的规定和服务器手册的装配指导,以确保符合现有的产品认证和 批。仅使用本指南中描述和规定的指定组件。使用其他产品 / 组件将使产品的 认证和其他管理审批无效,并可能导致产品不符合销售地的产品法规。 安全警告与注意事项 为避免人身伤害与财产损失,安装本产品之前,请阅读以下所有安全指导和信息 下面所列的安全符号可能在整个文档中使用并可能标注于产品和 / 或产品包装之上。 注意 表示如果无视此“? ? ? 项”? ? ? ? ? ? ? 轻微人身伤害或财产损失的危 警告 表示如果无视此“? ? ”? ? ? ? ? ? ? 严重人身伤害的危险。...
  • Page 211 • 远离振动源或物理震动。 • 与电气设备产生的强大电磁场隔离。 • 在易受闪电袭击的地区,我们建议将系统插入电涌抑制器并在闪电期间断开通信 线路与调制解调器之间的连接。 • 提供正确接地的墙壁插座。 • 提供足够的空间,以便拿取电源供应线,因为这是本产品的主要电源断开器。 设备操作规范 减少人身伤害或设备受损的危险: • 移举设备时遵守当地的职业健康与安全要求。 • 借助机械手段或其他合适的手段移举设备。 • 拆除一切易分离组件,以降低重量并方便操作。 电源与电气警告 注意事项 电源按钮(如待机电源标记所示)并不能完全关闭系统的交流电源,只要系统已接 通电源,就存在 5V 待机电源。要从系统切断电源,须从墙壁电源插座中拔下交流电线。您的系统可能 不止使用一根交流电线。请确保所有的交流电线都已拔下。打开机箱或增加或去除 任何热插拔组件之前,确保交流电线已拔下。 若非所需的确切类型,请勿尝试修改或使用交流电线。系统的每个电源供应设备都 需要一根单独的交流电线。 本产品的电源供应设备包含非用户维修部件。请勿打开电源供应设备。电源供应设 备包含非常危险的电压级、电流级和能量级。请与生产商联系维修事宜。 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线,再将其 从服务器上移除。 ® Intel Server System S7000FC4UR Product Guide...
  • Page 212 ⎯ 电源线须拥有适合插座的安全接地插头或触点。 • 电源线为交流电源的主要断开设备。插座须靠近设备并可随时断开。 • 电源线须插入所提供的拥有合适接地的插座。 系统使用警告 注意事项 为避免人身伤害或财产损失,无论何时检查产品内部,以下安全指导都适用: • 关闭所有与本产品相连的外设。 • 按下电源按钮至关闭状态,关闭系统。 • 从系统或墙壁插座上拔下所有交流电线,断开交流电源。 • 断开与系统相连的所有线缆和通信线路。 • 卸除舱口盖时,保留所有螺钉及其他紧固件。完成产品内部检查之后,请 用螺钉或紧固件重新固定舱口盖。 • 请勿打开电源供应设备。电源供应设备内没有可维修部件。请与生产商联系 维修事宜. • 增加或替换任何非热插拔组件之前,请关闭服务器电源并断开所有电源线 。 • 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线 ,然后再从服务器上移除电源供应设备。 注意事项 如果服务器一直在运行,任何已安装的处理器和吸热设备都可能很热。除非要增加 或移除热插拔组件,否则请待系统冷却后再开盖。为避免在热插拔组件安装过程中 接触灼热组件,移除或安装热插拔组件时务须小心。 ® Intel Server System S7000FC4UR Product Guide...
  • Page 213 注意事项 为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸 下风机防护装置运行系统。 机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机 架生产商提供的安装说明进行安装。 从下往上将设备安装在机架上,最重的设备安装在机架的最底层。 一次只从机架上安装一件设备。 您须负责安装整个机架装置的主要电源断开设备。此主要断开设备须随时可用,且 须标明为控制整个装置(而不仅限于服务器)的电源。 为避免潜在的电击危险,须对机架及其上所安装的每一件设备实行正确的安全接地 。 静电放电 (ESD) 注意事项 ESD 会损坏磁盘驱动器、主板及其他部件。我们建议您执行 ESD 工作站的所有步骤。如果没有 ESD 工作站,则采取一些静电放电保护措施,操作部件时,戴上与服务器上的机箱接地 或任何未喷漆金属表面连接的防静电腕带。 操作主板时始终保持小心。它们可能对 ESD 非常敏感。拿持主板时只接触边缘。从保护包装中或从服务器上取出主板后,请将 主板组件侧面朝上放置在无静电的接地表面上。请使用导电泡沫垫(若有),不要 使用主板包装。请勿将主板在任何表面上滑动。 ® Intel Server System S7000FC4UR Product Guide...
  • Page 214 其他危险 替换电池 注意事项 不正确替换电池可能导致爆炸危险。替换电池时,请只使用设备生产商推荐使用的 电池。 请按当地法规处置电池。 请勿对电池充电。 请勿拆卸、刺穿或以其他方式损坏电池。 冷却和气流 注意事项 按照说明小心布置线缆,尽量减少气流阻塞和冷却问题。 为保证适当的冷却和气流,运行系统时请确保机箱盖已安装。未安装机箱盖即运行 系统可能导致系统部件受损。安装机箱盖的步骤如下: 首先检查并确保系统内没有遗留的未固定工具或部件。 • 检查线缆、内插板和其他组件已正确安装。 • 按产品说明安装机箱盖。 • 激光外设或激光设备 注意事项 为避免幅射暴露和 / 或人身伤害: 请勿打开任何激光外设或激光设备的外壳 • 激光外设或激光设备为非用户维修设备 • 请与生产商联系维修事宜 ® Intel Server System S7000FC4UR Product Guide...
  • Page 215: Appendix D: Regulatory And Compliance Information

    Product EMC Compliance - Class A Compliance Note: Legally the product is required to comply with Class A emission requirements as it is intended for a commercial type market place. Intel targets 10db margin to Class A Limits • FCC / ICES-003 - Emissions (USA / Canada) Verification •...
  • Page 216: Certifications / Registrations / Declarations

    Ecology Declaration (International) Product Regulatory Compliance Markings This product is marked with the following Product Certification Markings: Table 12. Product Regulatory Compliance Markings Regulatory Region Marking Compliance cULus Listing Marks USA / Canada ® Intel Server System S7000FC4UR Product Guide...
  • Page 217 VCCI Marking (Class A) Japan BSMI Certification Taiwan Number & Class A Warning GOST R Marking Russia RRL MIC Mark Korea See the regulatory information document for additional information. China Compulsory China Certification Mark WEEE Mark ® Intel Server System S7000FC4UR Product Guide...
  • Page 218: Electromagnetic Compatibility Notices

    (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 219: Industry Canada (Ices-003)

    Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. ® Intel Server System S7000FC4UR Product Guide...
  • Page 220: Bsmi (Taiwan)

    RRL (Korea) English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4. Date of Manufacturer: Refer to date code on product 5.
  • Page 221: Regulated Specified Components

    Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable threshold limits or (2) an approved / pending RoHS exemption applies.
  • Page 222: End Of Life / Product Recycling

    End of Life / Product Recycling Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and / or take-back. ® Intel Server System S7000FC4UR Product Guide...
  • Page 223: Appendix E: Equipment Log

    Memory Board (B) Memory Board (C) Memory Board (D) SAS Riser Board I/O Riser Board Power Distribution Board ® Intel Remote Management Module 2 Front Panel I/O Board Control Module (with or without LCD) SAS Backplane Board Processor Speed and...
  • Page 224 Power Supply (P1) Power Supply (P2) Hot-plug PCI Express* Slot (1) Hot-plug PCI Express Slot (2) PCI Express Slot (3) PCI Express Slot (4) PCI Express Slot (5) PCI Express Slot (6) PCI Express Slot (7) Intel® Server System S7000FC4UR Product Guide...
  • Page 225: Appendix F: Warranty

    “as is” unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
  • Page 226: Extent Of Limited Warranty

    Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
  • Page 227: How To Obtain Warranty Service

    Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
  • Page 228 ® Intel Server System S7000FC4UR Product Guide...
  • Page 229: Appendix G: Getting Help

    Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). Before calling, fill out an Issue Report form. For the fastest service, please submit your form via the Internet.
  • Page 230: Latin America

    Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 ® Intel Server System S7000FC4UR Product Guide...
  • Page 231 Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 ® Intel Server System S7000FC4UR Product Guide...
  • Page 232 ® Intel Server System S7000FC4UR Product Guide...

Table of Contents