Yanmar 6LPA-STP2 Service Manual page 300

6lpa series
Hide thumbs Also See for 6LPA-STP2:
Table of Contents

Advertisement

ALTERNATOR
Stator Drive End Frame
1. Using an ohmmeter (Figure 11-22, (1)) check
the continuity of the stator drive end frame
circuit. The stator circuit should have electrical
continuity between the coil leads. If continuity is
not measured, replace the drive end frame
assembly.
Figure 11-22
Figure 11-22
2. Using an ohmmeter (Figure 11-23, (1)) check
the stator for shorts to ground. The stator circuit
when measured between the coil leads and
drive end frame should have no continuity. If
continuity is measured, replace the drive end
frame assembly.
Figure 11-23
Figure 11-23
11-14
Brushes
1. Check the exposed brush length using calipers
(Figure 11-24). If the measured length is below
the specified minimum, replace the brush
holder.
Brush length:
• Brush Length (Standard) 10.5 mm (0.413 in.)
(1)
• Brush Length (Minimum) 1.5 mm (0.059 in.)
Figure 11-24
0004847
(1)
0004848
© 2007 Yanmar Marine International
Alternator Service
Figure 11-24
6LPA Service Manual
0004849

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

6lpa-stzp2

Table of Contents