Yanmar 6LPA-STP2 Service Manual page 200

6lpa series
Hide thumbs Also See for 6LPA-STP2:
Table of Contents

Advertisement

FUEL SYSTEM
5. Slowly pump the tester handle and observe the
pressure gauge (Figure 6-40).
6. Read the pressure gauge when the injection
pressure begins to decrease. NOTICE: Judge if
the nozzle operates normally or not by listening
for the swishing sound.
• No. 2 opening pressure: 300 to 310 kgf/cm
29.42 to 30.40 MPa (4267 to 4409 psi)
Figure 6-40
Figure 6-40
• If No. 2 opening pressure is out of the specified
range, disassemble the nozzle and select the
appropriate adjusting shim from the chart and
replace the shim located at the upper portion of
the No. 2 pressure spring.
6-24
0.700 mm
(0.027 in.)
1.025 mm
(0.040 in.)
1.275 mm
2
(0.050 in.)
,
1.450 mm
(0.057 in.)
1.725 mm
(0.0679 in.)
2.050 mm
(0.080 in.)
Note: Changing the adjusting shim thickness
by 0.025 mm changes the injection
pressure by approximately 3.8 kgf/cm
0.37 MPa (54 psi). Change only one
adjusting shim (at the upper portion of
No. 2 pressure spring).
7. After the injection test, check for leakage from
from the injection hole (Figure 6-41). There
0005302
should be no leakage.
Figure 6-41
(1)
1 – Normal Spray During Operation
2 – Undesired - Leakage After Operation
3 – Normal - No leakage After Operation
8. Disassemble the nozzle after checking the No.
2 opening pressure.
© 2007 Yanmar Marine International
Fuel Injection Nozzle
Adjusting Shim Thickness
0.850 mm
(0.033 in.)
1.150 mm
(0.045 in.)
1.300 mm
(0.051 in.)
1.575 mm
(0.062 in.)
1.750 mm
(0.0688 in.)
-
(2)
Figure 6-41
6LPA Service Manual
1.000 mm
(0.039 in.)
1.175 mm
(0.046 in.)
1.425 mm
(0.056 in.)
1.600 mm
(0.0629 in.)
1.900 mm
(0.0748 in.)
-
2
,
(3)
0005304

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

6lpa-stzp2

Table of Contents