Korg Electronic Keyboard Parameter Manual page 695

Korg electronic keyboard user manual
Table of Contents

Advertisement

Dump Program
This command lets you send the internal memory's
Program data as a System Exclusive data dump. You
can choose to send all of the Programs from all of the
banks, all of the Programs from a single bank, or a
single Program.
For more information, see "System Exclusive Data
Dumps".
Dump Combination
This command lets you send the internal memory's
Combination data as a System Exclusive data dump.
You can choose to send all of the Combinations from
all of the banks, all of the Combinations from a single
bank, or a single Combination.
For more information, see "System Exclusive Data
Dumps".
Dump Drum Kit
This command lets you send the internal memory's
Drum Kit data as a System Exclusive data dump. You
can choose to send all of the Drum Kits from all of the
banks, all of the Drum Kits from a single bank, or a
single Drum Kit.
For more information, see "System Exclusive Data
Dumps".
Dump Wave Sequence
This command lets you send the internal memory's
Wave Sequence data as a System Exclusive data dump.
You can choose to send all of the Wave Sequences from
all of the banks, all of the Wave Sequences from a
single bank, or a single Wave Sequence.
For more information, see "System Exclusive Data
Dumps".
Dump Global Setting
This command lets you send the internal memory's
Global Settings data as a System Exclusive data dump.
For more information, see "System Exclusive Data
Dumps".
Dump Sequencer
This command lets you send the internal memory's
Sequencer data, including all Songs in memory, as a
System Exclusive data dump.
For more information, see "System Exclusive Data
Dumps".
System Exclusive Data Dumps
These commands allow the OASYS internal data to be
transmitted to another OASYS, MIDI data filter, or
computer in the form of MIDI System Exclusive data.
Global: Page Menu Commands
Select the desired command (refer to the following
table), and a dialog box will appear. Then, select the
bank or timbre etc. of the data to be dumped, and press
the OK button.
Programs of all banks, programs of one
Dump Program
bank, one program
Dump
Combinations of all banks, combinations
Combination
of one bank, one combination
All drum kits, drum kits of one bank, one
Dump Drum Kit
drum kit
Dump Wave
All wave sequences, wave sequences of
Sequence
one bank, one wave sequence
Global settings (except for the Drum Kits
Dump Global
and User Wave Sequences of Global
mode)
Dump Sequencer
All song data and region data
Sending SysEx data dumps
Do not touch the OASYS's switches or turn off the
power while data is being transmitted.
1. Connect the OASYS to the device that will receive
the data dump.
If you're using a computer that is able to receive
MIDI System Exclusive messages, connect the MIDI
IN connector of your computer's MIDI interface to
the OASYS's MIDI OUT connector.
If you are using a MIDI data filer, connect the
OASYS's MIDI OUT connector to the MIDI IN
connector of the MIDI data filer.
2. Select Global P1: MIDI.
3. The following illustration shows the dialog box
that will appear when "Dump Program" is
selected.
If To dump one bank select "Bank," or to dump one
program select "Single."
4. Press the OK button to transmit the data.
While the data is being transmitted, the display will
indicate "Now Transmitting MIDI Data."
The size of the data and the time required for
transmission will depend on the type of data.
The following table shows the size of each data dump,
and the time required.
Type of data to be
dumped
6467584...
Program All
7571456
Program Bank (I-A...I-E)
485376
Program Bank (I-F)
643072
485376...
Program Bank (U-A...U-G)
643072
Program Single (I-A...I-E)
3792
Program Single (I-F)
5024
Program Single (U-A...U-
3792...5024
G)
Combination All
15925504
Combination Bank
1137536
Dump Program
Data size
Time required
(Bytes)
(Sec.)
2213.9...
2589.5
165.1
218.8
165.1...218.8
1.2
1.7
1.2...1.7
5433.5
387.1
685

Advertisement

Table of Contents
loading

Table of Contents