COPIER>DISPLAY>HT-C
SUM-A-C
DisARCDATscreenAC-colorctrldiffer
Lv.2
Details
TodisplayC-patchcontroldifferenceofscreenAinARCDAT
control.
Whenhuevariationoccursandthedisplayedvalueisnotinthe
tolerablerange,executetheautogradationadjustment(reset
targetvalue).CheckthePatchSensororreplacethedeveloper
ifnotcorrected.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
SUM-A-K
DisARCDATscreenABk-colorctrldiffer
Lv.2
Details
TodisplayBk-patchcontroldifferenceofscreenAinARCDAT
control.
Whenhuevariationoccursandthedisplayedvalueisnotinthe
tolerablerange,executetheautogradationadjustment(reset
targetvalue).CheckthePatchSensororreplacethedeveloper
ifnotcorrected.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>DISPLAY>HT-C
SUM-B-Y
DisARCDATscreenBY-colorctrldiffer
Lv.2
Details
TodisplayY-patchcontroldifferenceofscreenBinARCDAT
control.
Whenhuevariationoccursandthedisplayedvalueisnotinthe
tolerablerange,executetheautogradationadjustment(reset
targetvalue).CheckthePatchSensororreplacethedeveloper
ifnotcorrected.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
SUM-B-M
DisARCDATscreenBM-colorctrldiffer
Lv.2
Details
TodisplayM-patchcontroldifferenceofscreenBinARCDAT
control.
Whenhuevariationoccursandthedisplayedvalueisnotinthe
tolerablerange,executetheautogradationadjustment(reset
targetvalue).CheckthePatchSensororreplacethedeveloper
ifnotcorrected.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8-99