COPIER>ADJUST>DENS

P-TG-K

AdjofATRcontrolBk-colortargetvalue
Lv.2
Details
ToadjusttheoffsetoftheATRpatchtargetvalueforBk.
Whenthetargetvaluedetermineduponinitializationischanged,
theT/Dratioisalsochanged.
Fogginganddensityincreasearealleviatedwhenthevalueis
smaller,andcarrieradherenceisalleviatedwhenitislarger.
Usecase
Whendensityfailures,fogging,andcarrieradherence,etc.occur
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
3)Make50printsofapprox.10%imageratio(ex.COPIER>
TEST>PG>TYPE:16)4times.
4)ExecuteAutoAdjustGradation>FullAdjust.
Caution
Execute the Auto Adjust Gradation first to increase the density. If
youadjusttheoffsetofthetargetvalue,foggingmightgetworse.
Display/adj/setrange
-4to4
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
Adjustment/Maintenance>AdjustImageQuality>AutoAdjust
Gradation>FullAdjust
Supplement/memo
-

DMAX-K

AdjD-maxctrlBkcolordenstargetVL
Lv.2
Details
Animagefailuremightoccurbecausethedensitytargetvalue
oftheD-maxcontrolbecomesoutofthesettingtabledueto
environmentchange.
AdjusttheoffsetoftheblackdensitytargetvalueofD-max
control.
TheoffsetisresetwhenD-maxcontrol(FullAdjust)isexecuted.
Usecase
Whenanyimagefailureoccursduetoenvironmentchange
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Donotusethisatthenormalservice.
Display/adj/setrange
-128to128
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8

8

COPIER>ADJUST>DENS

P-ALPHA

AdjustmentofPatchSensoralphavalue
Lv.1
Details
To adjust the adjustment coefficient alpha for the patch sensor .
Thevaluemultipliedby1000isdisplayedinthescreen.
WhenreplacingthePatchSensorUnit,enterthevalueofthe
servicelabel.
Usecase
WhenadensityreadingerrorofthePatchSensoroccurs
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
512to2047
Unit
-
Appropriatetargetvalue
1200
Defaultvalue
-
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>MISC-P>PT-LPADJ
Relatedusermode
-
Supplement/memo
alpha:RatioofP-wavetoS-wave

P-K-Y

AdjYcolorptchdensconvscoeffctk
Lv.2
Details
To adjust the yellow patch density conversion coefficient k value
ofthePatchSensor.
Thevaluemultipliedby100isdisplayedonthescreen.
Usecase
WhenthePatchSensorfailstoreadthedensity
Adj/set/operatemethod
-
Caution
-
Display/adj/setrange
0to2047
Unit
-
Appropriatetargetvalue
-
Defaultvalue
1700
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8-181
8-181