COPIER>ADJUST>HV-TR
2TR-T23
SectrnsATVCcrrnt:highhmdythin2nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndsideofthin
paperatsecondarytransferATVCcontrol(inhighhumidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
Increase/decreasethevalueby1whilecheckingthesymptom
eachtime.
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-N23
Relatedusermode
-
Supplement/memo
-
2TR-R1
SectrnsATVCcrrnt:lowhmdyrcycl1st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stsideof
recycledpaperatsecondarytransferATVCcontrol(inlow
humidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-N1
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>ADJUST>HV-TR
2TR-R2
SectrnsATVCcrrnt:lowhmdyrcycl2nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndside
ofrecycledpaperatsecondarytransferATVCcontrol(inlow
humidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-N2
Relatedusermode
-
Supplement/memo
-
2TR-R12
SectrnsATVCcrrnt:normhmdyrcycl1st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stsideof
recycledpaperatsecondarytransferATVCcontrol(innormal
humidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-N12
Relatedusermode
-
Supplement/memo
-
8-213
8-213