COPIER>ADJUST>DENS
DMLMT-LM
MtonerchargingDCvoltagelowerlimit
Lv.2
Details
ToadjusttheoffsetofthechargingDCvoltagelowerlimitforM
inD-maxcontrol.
Usecase
WhenafailureoccursduetolimiterofD-maxcontrol
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)ExecuteAutoAdjustGradation>QuickAdjust.
Caution
Donotusethisatthenormalservice.
Display/adj/setrange
-300to300
Unit
1V
Appropriatetargetvalue
-
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
Adjustment/Maintenance>AdjustImageQuality>AutoAdjust
Gradation>QuickAdjust
Supplement/memo
-
DMLMT-LC
CtonerchargingDCvoltagelowerlimit
Lv.2
Details
ToadjusttheoffsetofthechargingDCvoltagelowerlimitforC
inD-maxcontrol.
Usecase
WhenafailureoccursduetolimiterofD-maxcontrol
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)ExecuteAutoAdjustGradation>QuickAdjust.
Caution
Donotusethisatthenormalservice.
Display/adj/setrange
-300to300
Unit
1V
Appropriatetargetvalue
-
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
Adjustment/Maintenance>AdjustImageQuality>AutoAdjust
Gradation>QuickAdjust
Supplement/memo
-
8
8
COPIER>ADJUST>DENS
DMLMT-LK
BktonerchargingDCvoltagelowerlimit
Lv.2
Details
ToadjusttheoffsetofthechargingDCvoltagelowerlimitforBk
inD-maxcontrol.
Usecase
WhenafailureoccursduetolimiterofD-maxcontrol
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)ExecuteAutoAdjustGradation>QuickAdjust.
Caution
Donotusethisatthenormalservice.
Display/adj/setrange
-300to300
Unit
1V
Appropriatetargetvalue
-
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
Adjustment/Maintenance>AdjustImageQuality>AutoAdjust
Gradation>QuickAdjust
Supplement/memo
-
CONT-Y
ATRSensor(Y)controlvoltageentry
Lv.1
Details
ToenterthedensitydetectioncontrolvoltageofATRSensor(Y).
WhenreplacingtheDCControllerPCB/clearingRAMdata,enter
thevalueofservicelabel.
Usecase
WhenthebackupdataisclearedbyRAMclear,etc.
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
Afterthesettingvalueischanged,writethechangedvalueinthe
servicelabel.
Display/adj/setrange
32to68
Unit
0.1V
Appropriatetargetvalue
32to68
Defaultvalue
-
Requiredtime
-
Relatedservicemode
COPIER>DISPLAY>DENS>CONT-Y
Relatedusermode
-
Supplement/memo
-
8-184
8-184