COPIER>ADJUST>HV-TR
2TR-E22
SectrnsATVCcrrnt:normhmdyenvlp2nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndside
ofenvelopeatsecondarytransferATVCcontrol(innormal
humidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-P22
Relatedusermode
-
Supplement/memo
-
2TR-E13
SectrnsATVCcrrnt:highhmdyenvlp1st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stsideof
envelopeatsecondarytransferATVCcontrol(inhighhumidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-P13
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>ADJUST>HV-TR
2TR-E23
SectrnsATVCcrrnt:highhmdyenvlp2nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndsideof
envelopeatsecondarytransferATVCcontrol(inhighhumidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-P23
Relatedusermode
-
Supplement/memo
-
2TR-SH23
SectrnsATVCcrrnt:highhmdyhvy22nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndside
ofheavy2paperatsecondarytransferATVCcontrol(inhigh
humidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-H23
Relatedusermode
-
Supplement/memo
-
8-218