COPIER>OPTION>FNC-SW

SM-PSWD

Passwordsettingforservicetechnician
Lv.2
Details
Tosetpasswordforservicetechnicianthatisusedwhengetting
intoservicemode.
Usecase
Whenpasswordisrequiredtogetintoservicemode
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Besuretoselect1or2withPSWD-SWinadvance.
Display/adj/setrange
1to99999999
Unit
Appropriatetargetvalue
Defaultvalue
11111111
Requiredtime
Relatedservicemode
COPIER>OPTION>FNC-SW>PSWD-SW
Relatedusermode
Supplement/memo

RPT2SIDE

Setofreport1sided/2-sidedoutput
Lv.1
Details
Tosetwhethertouse1-sidedor2-sidedforreportoutputof
servicemode.
Usecase
Whenmaking2-sidedreportoutputtoreducethenumberof
outputpages
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to1
0:1-sided,1:2-sided
Unit
Appropriatetargetvalue
Defaultvalue
1
Requiredtime
Relatedservicemode
COPIER>FUNCTION>MISC-P>P-PRINT
Relatedusermode
Supplement/memo
8

8

COPIER>OPTION>FNC-SW

BRWS-FAV

Setofservicebrowserfavoriteregister
Lv.2
Details
Tosetwhethertoallowregistrationoffavoritesinthebrowserfor
service.
When1isset,favoritesinthebrowserforservicecanbeedited,
andanyURLscanbeaccessed.
Usecase
Whenserviceengineerseditfavoritesinthebrowserforservice
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to1
0:Disabled,1:Enabled
Unit
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo

PSCL-MS

Setautogradationadjoperation:heavy
Lv.1
Details
Tosetatwhichspeed(1/1speed,1/2speed,or1/3speed)
PASCALcontrolandD-halfcontrolareexecutedatautogradation
adjustment.
When"2"isset,theyareexecutedforthelastlyusedspeedonly.
Requiredtimeforautogradationadjustmentisshortwhileittakes
timetoswitchtootherspeed.
This is suitable for the users who frequently use a specific paper
type.
When"3"isset,theyareexecutedforallspeedssimultaneously.
Requiredtimeforautogradationadjustmentislong(approx.3
minutes)whileitisquicktoswitchtootherspeed.Thisissuitable
fortheuserswhousevariouspapertypes.
Usecase
Whensettingthespeedaccordingtothematerialsusedbythe
user
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
2to3
2:Lastlyusedspeed,3:Allspeeds
Unit
Appropriatetargetvalue
Defaultvalue
2
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
8-279