COPIER>ADJUST>HV-TR
2TR-SH13
SectrnsATVCcrrnt:highhmdyhvy21st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stsideof
heavy2paperatsecondarytransferATVCcontrol(inhigh
humidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-H13
Relatedusermode
-
Supplement/memo
-
2TR-E1
SectrnsATVCcrrnt:lowhmdyenvlp1st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stsideof
envelopeatsecondarytransferATVCcontrol(inlowhumidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-P1
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>ADJUST>HV-TR
2TR-E2
SectrnsATVCcrrnt:lowhmdyenvlp2nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndsideof
envelopeatsecondarytransferATVCcontrol(inlowhumidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-P2
Relatedusermode
-
Supplement/memo
-
2TR-E12
SectrnsATVCcrrnt:normhmdyenvlp1st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stside
ofenvelopeatsecondarytransferATVCcontrol(innormal
humidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-P12
Relatedusermode
-
Supplement/memo
-
8-217