COPIER>OPTION>FNC-SW
DMX-DISP
ON/OFFautogrdtnadjD-maxPASCALctrl
Lv.1
Details
TosetwhethertoexecuteD-maxPASCALcontrolatfull
adjustmentofautogradationadjustment.
When"0:ON"isset,D-maxPASCALcontrolandPASCALcontrol
areexecuted.FourA4-sizesheetsareusedfortestprints(Onefor
D-maxPASCALcontrolandthreeforPASCALcontrol)
When"1:OFF"isset,PASCALcontrol(gradationadjustment)
onlyisexecuted.ThreeA4-sizesheetsareusedfortestprints(for
PASCALcontrol).
Usecase
Whenmakingthesettingaccordingtotheusageoftheuser
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to1
0:ON,1:OFF
Unit
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
STND-PNL
Setof3-DControlPanelinstallation
Lv.2
Details
[Notused]Tosetwhetherthe3-DControlPanelisinstalled.
Whenthe3-DControlPanelisinstalled,set"1:Installed".
Usecase
Atinstallationofthe3-DControlPanel
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to1
0:Notinstalled,1:Installed
Unit
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
8
8
COPIER>OPTION>FNC-SW
INVALPDL
DisableofPDLlicense
Lv.1
Details
TodisabletheregisteredPDLlicense.
When"1:Disabled"isset,PDLisdisabledevenifaPDLlicense
isregistered.Thisissettothemachinesinstalledatconvenience
stores,whichdonotallowPDLtobeused.
Usecase
WhenprohibitingtheuseofPDL
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to1
0:RegisteredPDLlicenseisenabled,1:Disabled
Unit
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
IMGCNTPR
Settingofimagequalitymode
Lv.1
Details
Tosettheimagequalitymode.
Thecounterprioritymodeisappliedwhen1isset,andtheimage
qualityprioritymodeisappliedwhen0isset.
Usecase
Uponuser'srequest
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to1
0:Imagequalityprioritymode,1:Counterprioritymode
Unit
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
8-280
8-280