Ecode Detail
Location
Item
Code
E602
1410
00
Title
ErrorinHDD
Description SystemerrororPacketdataerror
Remedy
It'sduetodatacorruptionorsoftwarebug.
1.StartinSafeModetoperformoverallformatwithSSTand
reinstallthesystem(System,Lang,RUI),andthenturnOFF
andthenONtheMainPowerSwitch.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
E602
1411
00
Title
ErrorinHDD
Description FailureinHDDconnection
Remedy
ThisistheerrorwhichusuallydoesnotoccurinRead/Write
level.
1.Checkthecableandpowerconnector.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
E602
1412
00
Title
ErrorinHDD
Description SystemerrororPacketdataerror
Remedy
It'sduetodatacorruptionorsoftwarebug.
1.StartinSafeModetoperformoverallformatwithSSTand
reinstallthesystem(System,Lang,RUI),andthenturnOFF
andthenONtheMainPowerSwitch.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
E602
1413
00
Title
ErrorinHDD
Description WriteAbort
Remedy
Thedocumentdata(suchasBOXontheHDD)canbe
damaged.
1.EntertheapplicableCHK-TYPE=8inthepartitionto
performHDD-CHECK(duration:severalminutestoseveral
dozensofminutes),andthenturnOFFandthenONthe
power.
2.Iftheabovemeasuresdonotsolvetheproblem,enterthe
applicableCHK-TYPE=8inthepartitiontoexecuteHDD-
CLEAR,andthenturnOFFandthenONtheMainPower
Switch.
(UseSSTtoperformreformat/reinstallationinthecaseof
thefollowing:BOOTDEV,BOOTDEV2andAPL_SEND)
3.Iftherestillremainstheproblem,itcanbecausedby
failurewiththeHDD;therefore,replacetheHDDand
reinstallthesystem.
7

Description
7

Ecode Detail
Location
Item
Code
E602
1414
00
Title
ErrorinHDD
Description SystemerrororPacketdataerror
Remedy
It'sduetodatacorruptionorsoftwarebug.
1.StartinSafeModetoperformoverallformatwithSSTand
reinstallthesystem(System,Lang,RUI),andthenturnOFF
andthenONtheMainPowerSwitch.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
E602
1421
00
Title
ErrorinHDD
Description FailureinHDDconnection
Remedy
ThisistheerrorwhichusuallydoesnotoccurinRead/Write
level.
1.Checkthecableandpowerconnector.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
E602
1422
00
Title
ErrorinHDD
Description SystemerrororPacketdataerror
Remedy
It'sduetodatacorruptionorsoftwarebug.
1.StartinSafeModetoperformoverallformatwithSSTand
reinstallthesystem(System,Lang,RUI),andthenturnOFF
andthenONtheMainPowerSwitch.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
E602
1423
00
Title
ErrorinHDD
Description SystemerrororPacketdataerror
Remedy
It'sduetodatacorruptionorsoftwarebug.
1.StartinSafeModetoperformoverallformatwithSSTand
reinstallthesystem(System,Lang,RUI),andthenturnOFF
andthenONtheMainPowerSwitch.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
E602
1424
00
Title
ErrorinHDD
Description SystemerrororPacketdataerror
Remedy
It'sduetodatacorruptionorsoftwarebug.
1.StartinSafeModetoperformoverallformatwithSSTand
reinstallthesystem(System,Lang,RUI),andthenturnOFF
andthenONtheMainPowerSwitch.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
7-53
Description
7-53