COPIER>ADJUST>CCD
DFTAR-B
Shadingtargetvalue(B)[Frontside]
Lv.1
Details
WhenreplacingtheReaderControllerPCB,enterthevalueof
servicelabel.
WhenreplacingtheCopyboardGlass/ScannerUnit(paperfront),
executeCOPIER>FUNCTION>CCD>DF-WLVL1,DF-WLVL2
andwritethevaluewhichisautomaticallysetintheservice
label.
•
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
•
WhenreplacingtheCopyboardGlass/ScannerUnit(paper
front)
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
700to1400
Unit
-
Appropriatetargetvalue
-
Defaultvalue
1209
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>DF-WLVL1,DF-WLVL2
Relatedusermode
-
Supplement/memo
-
MTF2-M1
MTFvalue1setting:horzscan[Front]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to80
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>ADJUST>CCD
MTF2-M2
MTFvalue2setting:horzscan[Front]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to80
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
MTF2-M3
MTFvalue3setting:horzscan[Front]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to80
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
MTF2-M4
MTFvalue4setting:horzscan[Front]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to80
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
8-159
8-159