Vp-Txt; P-Alpha, Pascl-Ty; Ast-Sel - Canon imageRUNNER ADVANCE C5045 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5045 Series:
Table of Contents

Advertisement

COPIER>OPTION>IMG-MCON

VP-TXT

Settingofcharactervectorization
Lv.2
Details
Tomakeasettingofvectorconversionprocessingfortexton
scalablePDF.
Inthevectorconversionprocessing,abinaryimageoutlineis
extracted in the field which is recognized as text, and is converted
intovectordata.
Inregularvectorconversion,functionapproximationisnotused
forsmalltextbecausetheimagequalityisnotchanged.
Whenthevalueischanged,functionapproximationprocessingis
executedforsmalltext,whichrealizessmoothtextalthoughthe
imagequalityischanged.
Changethisvaluewhenyouwanttoprioritizesmoothnessin
smalltext.
Usecase
Uponuser'srequest
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to99
Unit
Appropriatetargetvalue
Defaultvalue
1
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
PASCL-TY
Papersettingforautogradationadj
Lv.2
Details
Autogradationadjustmentisnormallyexecutedwiththe
recommended paper specified for each location. However, if you
wanttochangethepapertype,usethissettingtochangethe
papertype.
Usecase
Whenexecutingtheautogradationadjustmentusingapaper
otherthantherecommendedpapertype
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Donotchangethesettinginthenormaloperation.
Display/adj/setrange
1to3
1:CS-814(ExceptforUSAandEU.MainlyforJapan)
2:Hammermill(ForUSA)
3:Mondi(ForEU)
Unit
Appropriatetargetvalue
Defaultvalue
Thevaluediffersaccordingtothelocation.
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
8

8

COPIER>OPTION>IMG-MCON
P-ALPHA
AdjustmentofPatchSensoralphavalue
Lv.1
Details
To adjust the correction coefficient alpha value of the Patch
Sensor.
Thevaluemultipliedby1000isdisplayedonthescreen.
WhenreplacingthePatchSensor,enterthevalueofservice
label.
Usecase
WhenthePatchSensorfailstoreadthedensity
Adj/set/operatemethod
1)Enterthesettingvalue.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
512to2047
Unit
Appropriatetargetvalue
1200
Defaultvalue
Requiredtime
Relatedservicemode
COPIER>FUNCTION>MISC-P>PT-LPADJ
Relatedusermode
Supplement/memo

AST-SEL

Adjofadvancedsmoothingeffect
Lv.2
Details
Toadjustthesmoothingeffectwhichissetintheadvanced
smoothingUI.
Set3ifnosmoothingeffectisobtainedeventhoughStrongisset
intheadvancedsmoothingUI.
Set0iftoomucheffectisobtainedeventhoughWeakissetinthe
advancedsmoothingUI.
Usecase
Whenimagefailures(jaggy,moire)occur
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to3
Unit
Appropriatetargetvalue
Defaultvalue
2
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
AST:AdvancedSmoothingTechnology