Cldf1-En; Bwdf1-En - Canon imageRUNNER ADVANCE C5045 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5045 Series:
Table of Contents

Advertisement

COPIER>FUNCTION>MISC-R

CLDF1-EN

ClrfrontstreamreadMTFVLinitialset
Lv.1
Details
ToreturntheMTFvalueforcolorfrontsidestreamreadingtothe
factorysettingvalue.
Sinceoverwritingisperformedwiththebackupdataretainedin
theReaderControllerPCB,theMTFvalueobtainedbysampling
oftheMTFchartbecomesdisabled.
WhenCLM-DF1isexecuted,thevalueisautomaticallysetto1.
Whenthevalueissetto0,thevalueadjustedwithCLM-DF1
becomesdisabledandreturnedtothefactorysettingvalue.
Usecase
WhenreturningtheMTFvaluetotheinitialsettingvalueupon
user's request in case that a sufficient quality level cannot be
obtainedonthefrontsideofacolorimageevenperforminga
fine adjustment with CLM-TGT after adjusting the MTF value
withCLM-DF1.
Adj/set/operatemethod
Selecttheitem,andthenpressOKkey.
Caution
TheMTFvalueobtainedbyreadingtheMTFchartbecomes
disabled.
Display/adj/setrange
0to1
0:Factorysettingvalue,1:Adjustmentvalueatinstallation
Unit
-
Appropriatetargetvalue
-
Defaultvalue
-
Requiredtime
Approx.1minute
Relatedservicemode
COPIER>FUNCTION>MISC-R>CLM-DF1,CLM-TGT
COPIER>ADJUST>CCD>MTF2-M1to12,MTF2-S1to12
Relatedusermode
-
Supplement/memo
-
8

8

COPIER>FUNCTION>MISC-R

BWDF1-EN

B&WfrontstreamreadMTFVLinitialset
Lv.1
Details
ToreturntheMTFvalueforB&Wfrontsidestreamreadingto
thefactorysettingvalue.
Sinceoverwritingisperformedwiththebackupdataretainedin
theReaderControllerPCB,theMTFvalueobtainedbysampling
oftheMTFchartbecomesdisabled.
WhenBWM-DF1isexecuted,thevalueisautomaticallysetto1.
Whenthevalueissetto0,thevalueadjustedwithBWM-DF1
becomesdisabledandreturnedtothefactorysettingvalue.
Usecase
WhenreturningtheMTFvaluetotheinitialsettingvalueupon
user's request in case that a sufficient quality level cannot be
obtainedonthefrontsideofaB&Wimageevenperforminga
fine adjustment with BWM-TGT after adjusting the MTF value
withBWM-DF1.
Adj/set/operatemethod
Selecttheitem,andthenpressOKkey.
Caution
TheMTFvalueobtainedbyreadingtheMTFchartbecomes
disabled.
Display/adj/setrange
0to1
0:Factorysettingvalue,1:Adjustmentvalueatinstallation
Unit
-
Appropriatetargetvalue
-
Defaultvalue
-
Requiredtime
Approx.1minute
Relatedservicemode
COPIER>FUNCTION>MISC-R>BWM-DF1,BWM-TGT
COPIER>ADJUST>CCD>MTF2-M1to12,MTF2-S1to12
Relatedusermode
-
Supplement/memo
-
8-260
8-260

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents