● Procedure for organizing a room
1
Click [Setup] in the "Round QSO room settings" screen on the "Settings" window
The "Room Open" window will appear.
2
Input or select the necessary items
3
Click [Room Activation]
The changed information is sent to the WIRES-X server.
4
Click [OK]
Will save the settings and the "Settings" will appear again.
Room Active ...............................Putting a check-mark here allows you to make your room active.
Serial No .....................................Your HRI-200 serial number (unchangeable)
DTMF ID .....................................Your node access code for the analog station (unchangeable)
Room ID .....................................Access code of your room for the digital station
Style
Choose between three different types of room operation.
Tip
The default setting is open.
• Open.........................................Selecting this will set up a room with no connection user restrictions.
• Closed ......................................Selecting this will set up a room that can only be used by nodes or stations of registered
• GM ............................................Selecting this sets up a GM dedicated room that can only be utilized by nodes and stations
How to Use
Un-checking the check-mark here stops operation of your room. (Default setting)
You can change up to 16 alphanumeric characters. Clicking [Room Activation] after changing
the entry, sends the changed Room ID to the WIRES-X server and updates the room list.
Tip
If the changed room ID is already in use, clicking [Room Activation] will cause an error message to
appear. If this happens, change the entry, and use a different alphanumeric string.
members.
Cautions
• In closed rooms, only digital nodes of registered members can connect. To connect an analog node,
select the open-room operation.
• In closed rooms, the communications mode only repeats the audio of "DN" (the "DN" mode
transmits audio & data simultaneously). To repeat the audio of "VW" (the "VW" mode transmits
digital audio at the full rate), select the open-room operation.
registered as GM operation members. This is only selectable when the operation mode of the
node (See page 23) is a "Digital" (1 station configuration) is set.
Caution
In GM rooms, the communication mode that can be repeated is limited to the audio of "DN" or the
digital data (excluding images) of "DW" (mode that only transmits data).