Kyocera FS-C8520MFP Service Manual page 344

Hide thumbs Also See for FS-C8520MFP:
Table of Contents

Advertisement

Connector
Pin
1
IH_FAN1_RE
YC24
M
Connected to
2
GND
IH fan motor
3
IH_FAN1_AL
M
1
24VIL2
YC25
Connected to
2
24VIL1
right cover
3
24VIL1
switch, front
4
24V4
cover switch
5
3.3V0
1
BDY
YC26
Connected to
2
BDC
main PWB
3
BDM
4
BDBK
5
NC
6
EME_IRN
7
EME_DIR
8
EME_BSY
9
EME_SO
10
EME_SI
11
EME_CLK
12
PAGEST
13
OVSYNCMON
14
PVSYNC
15
AQUA_RDY
16
AQUA_SEL
17
AQUA_SO
18
AQUA_SI
19
AQUA_CLK
20
HYP_INT
21
HYP_SDA
22
HYP_SCL
23
GND
24
GND
25
GND
26
GND
Signal
I/O
O
0/24 V DC
-
-
I
0/3.3 V DC
I
24 V DC
O
24 V DC
O
24 V DC
I
24 V DC
O
3.3 V DC
O
0/3.3 V DC (pulse) Horizontal synchronizing signal (Yellow)
O
0/3.3 V DC (pulse) Horizontal synchronizing signal (Cyan)
O
0/3.3 V DC (pulse) Horizontal synchronizing signal
O
0/3.3 V DC (pulse) Horizontal synchronizing signal (Black)
-
-
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC (pulse) Serial communication data signal input
O
0/3.3 V DC (pulse) Serial communication data signal output
I
0/3.3 V DC (pulse) Clock signal
O
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC (pulse) Vertical synchronizing signal
I
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC (pulse) Serial communication data signal input
O
0/3.3 V DC (pulse) Serial communication data signal output
O
0/3.3 V DC (pulse) Clock signal
I
0/3.3 V DC
O
0/3.3 V DC (pulse) Data signal
O
0/3.3 V DC (pulse) Clock signal
-
-
-
-
-
-
-
-
Voltage
IHFM: On/Off
GROUND
IHFM alarm signal
24 V DC power input from RCSW
24 V DC power output to RCSW
24 V DC power output to FCSW
24 V DC power input from FCSW
3.3 V DC power output to FCSW
(Magenta)
Not used
Interruption signal
Communication direction change signal
Busy signal
Sub-scanning standard signal
Sub-scanning monitor signal
Ready signal
Select signal
Interruption signal
GROUND
GROUND
GROUND
GROUND
2-3-18
2MY/2MZ
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-c8525mfp

Table of Contents