(4) Detaching and refitting the registration cleaner

Procedure
1. Open the front cover. (See page 1-5-3)
2. Open the duct cover. (See page 1-5-15)
3. Set the cleaner lever (yellow) up and
draw the registration cleaner frontward.
4. Check or replace the registration
cleaner and refit all the removed parts.

(5) Detaching and refitting the MP tray

Procedure
1. Open the MP tray.
2. Release two fulcrums of the MP tray by
using a flat screwdriver.
3. Pull two straps upwards to remove.
4. Remove the MP tray.
Registration cleaner
Figure 1-5-21
Flucrum
Flat screwdriver
Figure 1-5-22
1-5-13
2MY/2MZ
Cleaner lever
q
(yellow)
_
Flucrum
Flat screwdriver
Straps
MP tray