Item No.
U107
Setting the voltage for the intermediate transfer cleaning
Description
Sets the control voltage for the intermediate transfer cleaning.
Purpose
To change the setting when the offset by a defective cleaning of the transfer belt is generate.
Method
1. Press the start key.
2. Select the item. The screen for executing each item is displayed.
Belt(A)
Belt(B)
Belt(C)
Setting
1. Select the item to be set.
2. Change the setting value using the cursor left/right keys or numeric keys.
Display
Full
Half
3/4
B/W Full
B/W Half
B/W 3/4
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Display
Correction value of belt A
Correction value of belt B
Correction value of belt C
Description
Full speed printing of color
Half speed printing of color
75% of full speed printing of color
Full speed printing of monochrome 0 to 200
Half speed printing of monochrome 0 to 200
75% of full speed printing of
monochrome
Description
Description
Setting
range
0 to 200
0 to 200
0 to 200
0 to 200
1-3-51
2MY/2MZ
Initial setting
20ppm
25ppm
10/72/72
13/90/90
9/45/45
9/45/45
9/54/72
10/68/90
10/60/60
13/90/90
9/42/42
9/68/68
9/35/35
10/45/45