(5) Detaching and refitting the IH PWB

Procedure
1. Remove the scanner right cover.
(See page 1-5-5)
2. Remove the right upper cover.
3. Remove the right rear cover.
4. Remove two screws and then remove
the IH box cover.
5. Remove all connectors from the IH
PWB.
6. Remove six screws and then remove
the IH PWB.
7. Check or replace the IH PWB and refit
all the removed parts.
Right upper cover
Screw
Screw
Screw
Screw
Screw
Screw
1-5-36
Right rear cover
Figure 1-5-64
IH PWB connectors
Screw
Screw
IH PWB
IH box cover
Figure 1-5-65