Galaxy NW-12

Troubleshooting

NO CONTROL
Image 9-13

Basic troubleshooting guide

208
NO POWER
BACK TO
STANDBY
LAMP ON
NO IMAGE
LAMP OFF
STRETCHED / SHRUNK IMAGE
ARTEFACTS
WRONG ORIENTATION
FLICKERING IMAGE
NOISE IN THE IMAGE
BAD ZOOM
BAD FOCUS
POOR IMAGE
BAD SOFT EDGE
BAD BRIGHTNESS or CONTRAST
NO RCU CONTROL
POWER CORD NOT HOT
POWER CORD NOT PLUGGED
MAINS SWITCH OFF
TEMP. OUT OF RANGE
HUMIDITY OUT OF RANGE
VERY HIGH ALTITUDE
PROJECTOR TILT
LAMP
NO SOURCE SELECTED
NO SOURCE SIGNAL FOUND
PROJECTOR IN STANDBY
Replace lamp
Switch on LFR
Replace lamp
Check the IG
Check cabling and connections
Adjust lens zoom
Adjust lens focus
ELECTRONIC SOFT EDGE
Set Brightness / Contrast
Clean the projector lens
Remove blocking objects
Program the correct address
Insert new batteries
R59770288 GALAXY NW-12, GALAXY NW-7 20/06/2013
Check external power supply
Replace the power cord
Plug in the power cord
Switch ON
Cool down the room
Bring humidity down
Place projector within tilt range
Replace lamp
Select a source
Connect a source
NOT CONNECTED
Check wires and connectors
Check image generator
Switch to active state
Set Aspect ratio
Set the Orientation
Enable Soft edge
Set Lamp power mode to Normal