8. Secure the line filter.
A. Using a Phillips head screwdriver, secure the two screws that hold the line filter to the
lower control board bracket.
9. Secure the wires.
A. Check to see that all of the cables are connected firmly in their proper place.
B. Tie the wires back with the wire ties on the base and be sure no wires get pinched.
C. Place the lower board shield in position and push the clips down. NOTE: The clips will
snap in.
10. Perform IR Compensation procedure.
A. Follow the IR Compensation procedure located in this chapter.
11. Secure the motor cover.
A. Lower the motor cover center into position. See Figure 2.
B. Using a Phillips head screwdriver, tighten the three screws on each side. Be sure the
screws are catching the center motor cover's holes. See Figure 2.
12. Calibrate speed.
A. Follow the Speed Calibration procedure located in this chapter.

Power Cord

NOTE: This procedure will cover the power cable, line filter and power switch.
Tools Required
• Phillips head screwdriver
• 3/8" Nutdriver or socket wrench
• ESD (Electro Static Discharge) grounding strap
! WARNING: Disconnect the power cord before beginning this procedure. Keep wet
1. Disconnect the external power source.
A. Turn the main power switch on the left side to the off (O) position.
B. Unplug the treadmill from the power outlet.
Service
Page 7-26
Cybex Pro+ Treadmill Owner's & Service Manual
items away from inside parts of the treadmill. Electrical shock could occur
even if the treadmill is unplugged. Do not touch components on the lower
board. A charge can remain after unplugging the power cord and turning
off the treadmill.

Hide quick links: