wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 8.2):
• the power supply for the appliance must be brought into
a switch box.
• the power can then be supplied from the switch box to the
appliance using a minimum of 14-3 with ground wire.
• at the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
• at the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as shown.
• add a 1/4 in. insulated female connector to the red (switch
leg) wire, route it through the knockout in the face of the
junction box, and connect to the top fan switch connector
(1/4 in. male) as shown.
Minimum 14-3 AWG
with Ground
Junction Box
Red
Figure 8.2 Junction Box wired to wall Switch or BC10
46
Quadra-Fire • SAPH-MBK-IPI, SAPH-D-PMH-IPI, SAPH-D-MBK-IPI, SAPH-D-CSB-IPI Installation Manual • 2343-980_R8 • 11/14
Switch
Red
Black
Black
White
White
Green
Green
Power
Switch Box
Supply
Wires
Knockout