C. Approved Pipe
this appliance is approved for use with hearth & home
technologies SlP venting systems. Refer to Section 11.a
for vent component information and dimensions.
DO NOT mix pipe, fittings or joining methods from different
manufacturers.
the pipe is tested to be run inside an enclosed wall. there
is no requirement for inspection openings at each joint
within the wall.
WARNING! Risk of Fire or Asphyxiation. This appliance
requires a separate vent. DO NOT vent to a pipe serving a
separate solid fuel burning appliance.
DO NOT USE FIELD-FABRICATED VENTING
COMPONENTS.
this product is approved to be vented either horizontally,
through the side wall or vertically through the roof. You may
vent through a Class a or masonry chimney if an approved
adapter is used.
this appliance is a direct vent heater. all combustion air must
come directly from the outside of the building. the vent pipe
for this unit consists of an inner and an outer pipe. the inner
pipe carries the appliance exhaust out of the system, and
the outer pipe brings fresh combustion air into the appliance.
• a round support box/wall thimble or heat shield is required
when the venting passes through a combustible wall.
• a support box or ceiling firestop is required when the
venting passes through a ceiling.
• Roof flashing and a storm collar are required when venting
passes through the roof.
• Follow instructions provided with the venting for installation
of these items.
11
Quadra-Fire • SAPH-MBK-IPI, SAPH-D-PMH-IPI, SAPH-D-MBK-IPI, SAPH-D-CSB-IPI Installation Manual • 2343-980_R8 • 11/14