INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions regarding installation, operation or service.
NOTICE: DO NOT discard this manual!
Models:
TOPAZ-MBK-IPI
TOPAZD-PMH-IPI
TOPAZD-MBK-IPI
TOPAZD-CSB-IPI
Solitaire
This appliance may be installed as an OEM installation
in manufactured home (USA only) or mobile home and
must be installed in accordance with the manufacturer's
instructions and the manufactured home construction
and safety standard, Title 24 CFR, Part 3280 or Standard
for Installation in Mobile Homes, CAN/CSA Z240MH, in
Canada.
This appliance is only for use with the type(s) of gas
indicated on the rating plate.
1
Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner's Manual • 2341-981_R4 • 10/15
Owner's Manual

Care and Operation

R
Cabinet Style
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury, or death.
- DO NOT store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- What to do if you smell gas
• DO NOT try to light any appliance.
• DO NOT touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified
installer, service agency, or the gas supplier.
DANGER
!
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for the
protection of the children and other at-risk
individuals.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire TOPAZ-MBK-IPI

  • Page 1: Care And Operation

    In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 2: Welcome

    00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 3: Table Of Contents

    C. Contact Information ......26  = Contains updated information. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 4: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645G 2/15 Page 1 of 2 Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 5 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645G 2/15 Page 2 of 2 Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 6: Product Specific Information

    B. Glass Specifications (Ceramic) This appliance is equipped with 5 mm ceramic glass. Replace glass only with 5 mm ceramic glass. Please contact your dealer for replacement glass. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 7: Important Safety And Operating Information

    • Teach children to NEVER touch the stove. technician to service the appliance. • Consider not using the stove when children will be present. Contact your dealer for more information, or visit: www. hpba.org/safety-information. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 8: General Operating Parts

    • Ensure that the glass is sealed and in the proper position and that the integral barrier is in place. WARNING! Risk of Fire or Asphyxiation! DO NOT operate stove with fixed glass assembly removed. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 9: Lighting Instructions (Ipi)

    Keep burner and control compartment clean. See installation and operating agency or the gas supplier. instructions accompanying appliance. For additional information on operating your Hearth & Home Technologies stove, please refer to www.fireplaces.com. 593-913i Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 10: Appliance Break-In

    If an optional fan is installed, the fan speed is controlled by adjusting the speed control knob. Turn the knob clockwise to increase the fan speed and counterclockwise to decrease the fan speed. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 11: Operation During A Power Outage (Ipi Plus)

    NOTICE: Some functionality will be lost when using battery backup including remote control, fan, or any other auxiliary functions that require household 110-120 VAC power. JUNCTION BOX Figure 3.6 Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 12: Detailed Component Operating Instructions

    Heat management for the fan is discussed in Section 3.G. Detailed instructions are included with the fan kit. LP/NG GAS-TYPE SELECTOR SWITCH WIRE LEAD FROM REGULATOR CONNECTS HERE Figure 3.7 Control Module Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 13: Maintenance And Service

    By: Homeowner Tools Needed: Protective gloves, glass cleaner, drop cloth and a stable work surface. PHILLIPS SCREWS CAUTION! Handle fixed glass assembly with care. Figure 4.2 Remove Glass Frame Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 14: Remote Control

    (building additions, decks, fences, or sheds). • Inspect for corrosion or separation. • Verify weather stripping, sealing and flashing remains intact. • Inspect draft shield to verify it is not damaged or missing. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 15: Maintenance Tasks - Qualified Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Figure 4.3 IPI Pilot Flame Patterns Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 16: Frequently Asked Questions And Troubleshooting

    This noise does not affect the operation or longevity of the appliance. Contact your dealer for additional information regarding operation and troubleshooting. Visit www.quadra-fire.com to locate a dealer. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 17: Troubleshooting

    D. Pilot valve solenoid. Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 18 Verify continuity with a multi-meter with ohms set at lowest range. Replace pilot if any damage is detected. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 19: Reference Materials

    Section 3 discusses using the fan to manage the heat output. Follow the instructions supplied with the fan kit to operate your fan. See your dealer if you have questions. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 20: Service Parts

    Beginning Manufacturing Date:July 2014 Gas Stove - DV Ending Manufacturing Date: Active TOPAZ-MBK-IPI, TOPAZD-CSB-IPI, TOPAZD-MBK-IPI, TOPAZD-PMH-IPI Log Set Assembly 17 18 19 20 Part number list on following page. 09/15 Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 21: Service Parts

    466-5030CSB Black 466-5020MBK Door Assembly Right, Quartet 466-5020PMH Mahogany 466-5020CSB Sienna Bronze Black 466-0010MBK Face 466-0010PMH Mahogany 466-0010CSB Sienna Bronze Additional service part numbers appear on following page. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 22 See Following Page Fan Shroud Assembly 2341-021 Back Fan Shroud 2341-129 On/Off Rocker Switch 060-511 Wire Harness, 30” 3-20-2159315 Top Mount 468-0420 Additional service part numbers appear on following page. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 23 Pkg of 5 303-315/5 22.9 Transformer, 6V 2326-131 22.10 Battery Pack 2166-323 22.11 Ball Valve Assembly, 24” 3-40-2098034 Blower Cord 832-2410 Additional service part numbers appear on following page. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 24 Bulkhead 7000-156 26.11 Gasket, Burner Neck 2025-407 26.12 Cover Plate 7010-159 26.13 7010-160 Gasket, Cover Plate 26.14 Gasket Spacer 2340-203 Additional service part numbers appear on following page. Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 25 Sienna Bronze WSLG-CSB Conversion Kits Conversion Kit NG NGKI-TIARA2 Conversion Kit LP LPKI-TIARA2 Pilot Ori ce NG 593-528 Pilot Ori ce LP 593-527 Regulator NG NGK-DXV-50 Regulator LP LPK-DXV-50 Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...
  • Page 26: Contact Information

    5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945C Printed in U.S.A. - Copyright 2014 Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15...