Table of Contents

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OwNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
GARN-MBK-IPI-B
GARN-DPMH-IPI-B
GARN-DMBK-IPI-B
GARN-DCSB-IPI-B
Solitaire
This appliance may be installed as an OEM installation
in manufactured home (USA only) or mobile home and
must be installed in accordance with the manufacturer's
instructions and the manufactured home construction
and safety standard, Title 24 CFR, Part 3280 or Standard
for Installation in Mobile Homes, CAN/CSA Z240MH, in
Canada.
This appliance is only for use with the type(s) of gas
indicated on the rating plate.
1
Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15
Installation Manual
Installation and Appliance Setup
R
Cabinet
!
wARNING: If the information in these instructions
is not followed exactly, a fire or explosion may result
causing property damage, personal injury, or death.
- DO NOT store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- what to do if you smell gas
• DO NOT try to light any appliance.
• DO NOT touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified
installer, service agency, or the gas supplier.
DANGER
!
HOT GLASS wILL CAUSE
BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOw CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for the
protection of the children and other at-risk
individuals.
In the Commonwealth of Massachusetts installation must
be performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire GARN-DMBK-IPI-B

  • Page 1 In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 2: Table Of Contents

    A. Leveling the Appliance ......27 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 3: Installation Standard Work Checklist

    Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2345-985_R1 4/15 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 4: Product Specific And Important Safety Information

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    (1/2) in. in size, “GAS VENT DIRECTLY Connection section additional BELOw. KEEP CLEAR OF ALL OBSTRUCTIONS”. Commonwealth of Massachusetts requirements. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 6: Getting Started

    Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300 ºF minimum continuous exposure rating) One 1/4 in. female connection (for optional fan). Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 7: Framing And Clearances

    Inches Millimeter 17-7/8 18-1/8 15-3/8 17-3/8 23-5/8 18-1/4 8-15/16 14-1/4 NOTE: Side view diagram show gas appliance equipped with optional blower, Part # BK-GAS Figure 3.1 Appliance Dimensions Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 8: Clearances To Combustibles

    GARN-DPMH-IPI-B GARN-DMBK-IPI-B 1403 1092 Millimeters GARN-DCSB-IPI-B D* and G*= Vented with minimum vertical pipe as shown. D** and G**= Horizontally vented, no vertical component. Figure 3.2 Appliance Locations Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 9: Termination Location And Vent Information

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 4.1 Minimum Height From Roof To Lowest Discharge Opening Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 10: Chimney Diagram

    • Vinyl protection kits are suggested for use with vinyl siding. Figure 4.3 Minimum Clearances for Termination Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 11: Approved Pipe

    • Roof flashing and a storm collar are required when venting passes through the roof. • Follow instructions provided with the venting for installation of these items. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 12: Use Of Elbows

    (flange of termination cap) (see Figure 4.3). • Vertical terminations are measured to bottom of termination cap. • Horizontal pipe installed level with 1/4 inch rise per foot. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 13: Venting Guidelines For Horizontal Runs

    3 ft (914 mm), i.e., plumbing tape • When penetrating a combustible ceiling, a ceiling firestop must be installed. REAR VENT 2 FT. (WITH VERTICAL RISE) MINIMUM Figure 4.6 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 14 Rear Vent - Horizontal Termination Natural Gas: No Elbow = 14 in. (356 mm) Maximum Propane: = 8 in. (203 mm) Maximum Figure 4.7 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 15 Rear Vent - Horizontal Termination - (continued) = 24 in. (610 mm) Maximum Back to Back 90° Elbows Only Note: This configuration is recommended for corner installations. Figure 4.8 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 16 Note: For optimum flame appearance, air shutter may need to Note: Flue restrictor may need to be adjusted as vertical be adjusted as vertical dimension increases. dimension increases. Figure 4.9 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 17 Note: Flue restrictor may need to be adjusted as vertical Note: For optimum flame appearance, air shutter may need to dimension increases. be adjusted as vertical dimension increases. INSTALLED HORIZONTALLY Figure 4.10 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 18 Note: For optimum flame appearance, air shutter may need to Note: Flue restrictor may need to be adjusted as vertical dimension increases. be adjusted as vertical dimension increases. Figure 4.11 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 19 Note: Flue restrictor may need to be adjusted as vertical Note: For optimum flame appearance, air shutter may need to dimension increases. be adjusted as vertical dimension increases. Figure 4.12 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 20 7. The connection between the appliance and the retro connector may be completed with sections of direct vent pipe. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 21 4 ft. (1m) of 3 in. (76mm) Flex Liner Air Intake Section Co-Axial to Co-Linear Connector (Part 46DVA - GCL) (Included in Chimney Liner Termination Kit) Figure 4.17 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 22 See Figure 4.19. of flex liner together. Connect the flex to the coupler by using four sheet metal screws for each side. See Figure 4.20. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 23 See Figure 4.22. Redrill larger holes on connector as needed. Be careful to ensure that the connector is centered in the opening and the mounting holes line up with the masonry wall. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 24 • May impair safe operation of this appliance or other appliances connected to the flue. • Vent this appliance directly outside. • Use separate vent system for this appliance. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 25: Vent Clearances And Framing

    Bottom: 1/2 in. (13 mm) Sides: 1 in. (25 mm) Figure 5.1 Horizontal Venting Clearances To Combustible Materials Inches 53-3/4 17-3/4 53-3/4 17-3/4 1365 1365 Figure 5.2 wall Penetration Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 26: Ceiling Firestop/Floor Penetration Framing

    Figure 5.3 Installing Ceiling Firestop INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 27: Appliance Preparation

    Normally, only one is required on the leg not touching the floor. Figure 6.2 2. Slide assembled nuts and bolts into slots on legs with the nuts on the bottom. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 28: Venting And Chimneys

    Use care when removing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent may leak. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 29: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner flue is not required. • All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 30: Secure The Vent Sections

    Figure 7.7 Rotate Seams for Disassembly 120º Figure 7.5 Securing Vertical Pipe Sections Figure 7.8 Align and Disassemble Vent Sections 120º Figure 7.6 Securing Horizontal Pipe Sections Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 31 2 in. (51 mm) MIN. BELOW FINISHED CEILING CUT HOLE 1/8 in. (3 mm) GREATER IN SIZE THAN PATTERN OF SUPPORT BOX AS IT IS PROJECTED ONTO ROOF LINE Figure 7.9 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 32: Vertical Termination Requirements

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 7.15. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 33 Tighten nut and make sure the collar is tight against the Caulk pipe section. • Caulk around the top of the storm collar. See Figure 7.15. Figure 7.15 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 34: Horizontal Termination Requirements

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be field constructed. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 35 HRC caps are available. When penetrating a brick wall, a brick extension kit is available for framing the brick. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 36: Electrical Information

    Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 37: Wiring Requirements

    6 volt transformer connected to permanent electrical service. FLAME IGNITER SENSE TO JUNCTION BOX (110V) MODULE FLAME MODULATION RC100 RC200 RC300 (OPTIONAL CONTROLS) BATTERY PACK 6V DC Figure 8.1 IPI wiring Diagram Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 38 Minimum 14-3 AWG with Ground Black Black White White Green Green Junction Box Power Switch Box Supply Wires Knockout Figure 8.2 Junction Box wired to wall Switch or BC10 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 39: Optional Fan Installation

    3. Holding the blower in place, attach it to the appliance with SNAP DISC four of the screws provided. See Figure 8.5. BRACKET SNAP DISC Figure 8.6 Install Snap Disc Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 40 Figure 8.8 Mount Speed Control Using Pal Nut VARIABLE SPEED SWITCH BLACK WHITE WHITE BLACK JUMPER (BLUE) JUNCTION BOX Figure 8.9 Fan wiring Diagram Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 41 8.10 (Wiring Diagram) IPI Module Aux Box Jumper Remove Variable Speed Switch and Connect Terminal ends Together White White Black Jumper (Blue) Junction Box Figure 8.10 Fan wiring Diagram Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 42: Gas Information

    1/2 in. (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 43: Air Shutter Setting

    • Slide the wing nut to the left to open the air shutter. • Tighten the wing nuts. NOTICE: If sooting occurs, provide more air by opening the air shutter. wING NUTS FOR SHUTTER ADJUSTMENT Figure 9.1 Air Shutter Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 44: Appliance Setup

    C. Clean the Appliance FRONT CASTING Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity. SAFETY BARRIER Figure 10.1 Remove Casting Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 45: Install The Log Assembly

    Log #3 (7016-170): Align hole on bottom of Log #3 with locating pin on Log #2. Position bottom of Log #3 into the notch on the right front of burner. See Figure 10.5. LocAtING PIN Figure 10.5 Figure 10.6 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 46: Install Fixed Glass Assembly

    20% closed. • If the vertical pipe on the vent run is between 20-25 feet, the restrictor should be approximately 33% closed. Loosen Screws Figure 10.7 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 47: Reference Materials

    8-11/16 in. 1-1/2 in. 12 in. 5-1/2 in. 220 mm 38 mm 146 mm 305 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 11.1 SLP Series Vent Components Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 48 26 in. 660 mm 14-7/16 in. 367 mm DVP-HSM-B 2-5/16 in. Extended Heat Shield 14-7/16 in. 59 mm 367 mm SLP-WT-BK Wall Thimble-Black Figure 11.2 SLP Series Vent Components Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 49 14 IN. 356 mm 12 IN. SLP-TB1 305 mm Horizontal Termination Cap STOVEDV-BK STOVEDV-BK Simpson Duravent Pipe Adapter Collar Pipe Adapter Collar Figure 11.3 SLP Series Vent Components Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 50 A. Vent Components Diagrams (continued) COAXIAL to COLINEAR VENTING LINK-DV30B 768-380A DV-46DVA-GCL Flex Liner Kit Stainless Steel Flex Pipe Coaxial/Colinear Appliance Connector LINKSQC-DV30 (COPPER) LINKSQB-DV30 (BLACK) Figure 11.4 SLP Series Vent Components Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 51 3” x 35’ Flex Extension 3DFA-35 4” x 35’ Flex Extension 4DFA-35 45° Elbow, Galvanized SLP45M 4DE45 45° Elbow, Black SLP45-BK See Swivel 4DE45B 45° Elbow, Swivel, Galvanized 46DVA-E45 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 52 LINK-STOVE Trapezoid Termination Kit (3-1/8”-4-3/4”) SLP-TRAP1 Trapezoid Termination Kit (5-1/4” X 9-1/4”) SLP-TRAP2 Vertical Termination Cap SLP-TVHW 46DVA-VCH * Stove Adaptor Kit (Vertical Cap Kit) Includes 30’-4” flex, adapters, wall thimble, masonry, ZC flashing, 991DA vertical cap NOTES: BeFoRe CuttING ANy hoLeS CheCK pIpe mANuFACtuReRS CuRReNt INStRuCtIoNS. eACh pIpe mANuFACtuReR hAS theIR owN LISt oF pARtS FoR KItS. SL IS NOT INTERChANGEABLE WITh SLP. Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...
  • Page 53: Accessories

    Please contact your Quadra-Fire dealer with any questions or concerns. For the location of your nearest Quadra-Fire dealer, please visit www. quadrafire .com. Printed in U.S.A. - Copyright 2015 Quadra-Fire • GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual • 2345-983_R2 • 07/15...

This manual is also suitable for:

Garn-dcsb-ipi-bGarn-mbk-ipi-bGarn-dpmh-ipi-b

Table of Contents