en | Settings
7.6

Outputs and Sirens

7.6.1

Outputs

Onboard / Extension Output
The AMAX panel is equipped with on-board outputs and supports DX3010 output extension
modules with each extension module supporting 8 relay outputs.
When on-board output 1 or 2 fails due to a short circuit or open circuit, as long as there is a
backup power supply, the output fault will not affect the normal operation of the whole
system, but will be detected by the system.
Each output is programmable and can be set to follow multiple events.
Depending on the type of output event, the output parameters can be defined as area output
or follow zone alarm output. The output polarity of each output can be programmed and
defined as three modes: continuous output, pulse output or inverted.
The maximum time of each output is specified by programming and will be automatically reset
after expiration.
Output Events
0 - Not used
1 - disarmed 0 = all areas, 1 -16 = areas1 - 16
The output operates on below conditions:
1.
2.
The output is reset:
1.
2.
2 - system armed 0 = all areas, 1-16 = areas1 - 16
The output operates on below conditions:
1.
System operated the arm command and until system is armed. (When system is operating the
arm command, the system will arm after the exit delay time is up.)
The output is reset:
1.
2.
If this duration is programmed as 000, the output will continue till the system disarmed.
3 - System Alarm
This output operates when an alarm occurs.
The output is reset:
1.
2.
When a new alarm has occurred, the alarm will reset the alarm time.
If this duration is programmed as 000, the output will continue till the zone is restore or
system is disarmed.
4 - System Alarm (audile and silent)
In case of audio alarm of the system, the output will be enabled.
2014.4 | 01 | F.01U.267.112
System disarmed after system reset.
System operated the disarm command.
When the system is armed.
When the output programmed duration is up.
System armed after system reset.
When the system is disarmed.
When the output programmed duration is up.
When the system is disarmed and alarm is reset.
When the output programmed duration is up.
Zone (alarm or tamper) programmed to disable zone silent alarm
System tamper / DX2010 tamper / keypad tamper
Keypad alarm (emergency alarm, fire alarm, medical aid alarm)
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Bosch Sicherheitssysteme GmbH
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icp-amax4-p2-enIcp-amax-p3-enAmax 4000Amax 4000en

Table of Contents