Bosch ICP-AMAX4-P1 Installation Manual page 108

Amax panel 4000; amax panel 4000 en
Hide thumbs Also See for ICP-AMAX4-P1:
Table of Contents

Advertisement

108
en | Address Programming
Unverified Alarm
Report / Cross Zone
Domestic Call
Common Area Settings
Option
Common area type
* AMAX 3000/4000
** AMAX 4000
2014.4 | 01 | F.01U.267.112
5
Receiver 1, 2, 3, and 4
6
Receiver 1 (2, 3, and 4 for backup)
7
Receiver 1 (where 2 for backup) and receiver 3 (where 4
for backup)
0
Disabled
1
Unverified alarm report
2
Cross zone
3
All
Follow 'alarm report' option's logic. range 0-7
0
No reports allowed
1
Report to destination 1
2
Report to destination 2
3
Report to destination 3
4
Report to destination 4
5
Report to destination 1 ,2, 3, and 4
6
Report to destination 1 (where 2, 3, and 4 are backup)
7
Report to destination 1 (where 2 is Backup) and 3 (where
4 is backup)
Address
0370
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Default
Value Range
0
0 = none
1 = Follow partition 2
2 = Follow partition 2-3*
3 = Follow partition 2-4 *
4 = Follow partition 2-5*
5 = Follow partition 2-6*
6 = Follow partition 2-7*
7 = Follow partition 2-8*
8 = Follow partition 2-9**
9 = Follow partition 2-10**
10 = Follow partition 2-11**
11 = Follow partition 2-12**
12 = Follow partition 2-13**
13 = Follow partition 2-14**
14 = Follow partition 2-15**
15 = Follow partition 2-16**
Bosch Sicherheitssysteme GmbH
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icp-amax4-p2-enIcp-amax-p3-enAmax 4000Amax 4000en

Table of Contents