Or in case of silent alarm of the system, the output will be enabled
In case of a new alarm event, the output time will be reset and re-timed.
When the output time is set to 000 and the alarm siren sounds for 0, the output will continue
until reset of alarm output or disarming of the system by the command of PIN 3 2 #.
The output of the following system alarm is only 1 second:
5 - External AWAY Siren
The output is triggered when:
System is AWAY armed +zone intruder alarm (intruder alarm = instant / interior instant /
delay / interior delay / delay exit / interior delay exit / follower / interior follower / 24h (can be
silenced) / Fire (can be silenced) / Technical Alarm (can be silenced))
System is AWAY armed +tamper alarm
(no alarm when panel is disarmed)
6 - External STAY Siren
The output is triggered when:
System is STAY armed +zone intruder alarm (intruder alarm = instant / interior instant / delay /
interior delay / delay exit / interior delay exit / follower / interior follower / 24h (can be
silenced) / Fire (can be silenced) / Technical Alarm (can be silenced))
System is STAY armed +tamper alarm
(no alarm when panel is disarmed)
7 - Internal Siren
The output is triggered when:
System is AWAY armed + zone intruder alarm (intruder alarm = instant / interior instant /
delay / interior delay / delay exit / interior delay exit / follower / interior follower / 24h (can be
silenced) / Fire (can be silenced) / Technical Alarm (can be silenced))
System is AWAY armed + tamper alarm
System is STAY armed + zone intruder alarm (intruder alarm = instant / interior instant /
delay / interior delay / delay exit / interior delay exit / follower / interior follower / 24h (can be
silenced) / Fire (can be silenced) / Technical Alarm (can be silenced))
System is AWAY armed + tamper alarm
System is disarmed + zone tamper alarm
When panel is armed = one pulse activation (1sec) (enabled / disable option can be combined
with disarm)
When panel is disarmed = two pulse activation (1sec) (enabled / disable option can be
combined with arm)
When Programming mode is entered = one pulse activation (1sec) (enabled / disable option)
8 - Internal Siren with tamper
The output is triggered when internal siren with tamper.
Bosch Sicherheitssysteme GmbH
Zone (alarm or tamper) programmed to enable zone silent alarm. In case of following
conditions, the output will be reset
Alarm reset
Arming of the system
Disarming of the system
Alarm siren test
Pacing (tamper / alarm / reset)
Key switch arming or- locking key switch disarming
Installation Guide
Settings | en
67
2014.4 | 01 | F.01U.267.112