Trouble Fault Inquiry

Fault Description
1 - Accessory Module Failure
Condition:
No communication with the DX4020 / ITS-DX4020G if DX4020 / ITS-DX4020G is programmed.
Restore:
Communication with DX4020 / ITS - DX4020G is normal and fault is reset.
Supervise:
1.
2.
3.
Condition:
No communication with DX3010 if DX3010 is programmed.
Restore:
2014.4 | 01 | F.01U.267.112
Network / IP Module 1 Failure
Report the DX4020 / ITS - DX4020G fault to configured destination on address 124 when
the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off, when there is no other system fault.
Output Expansion Module Failure
Both addresses 0144
and 0145 are set to 0
Extension system is used
in the telephone network
The telephone network
support ADSL as well
The zone silent alarm is
enabled
The transmission format
of the receiver is
programmed to 0 = not
used
The parameters of ITS-
DX4020-G are not
properly set.
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Program the address
0144 to a number from 1
to 15. Program the
address 0145 to 1
Add dial delay in
programming
Connect the system after
the ADSL filter
Disable the zone silent
alarm
Program the
transmission format of
the receiver to 1 or 3
Recommend to set the
parameter ACK TIMEOUT
of ITS-DX4020-G to the
maximum (600) and set
TRANSMIT BUFFER LIFE
TIME to the maximum
(120)