140
en | Troubleshooting
RPS cannot perform remote
programming and control
Occasionally abnormal
communication in use of
Contact ID/personal
telephone alarm
No response from the keypad
and the alarm siren
(disabled) when an alarm is
triggered by the zone
The AMAX panel cannot send
any reports (programmed to
send reports to receiver)
A-LINK cannot be connected
with ITS- DX4020-G
10.2
Trouble Fault Inquiry
Fault Description
1 - Accessory Module Failure
–
Condition:
No communication with the DX4020 / ITS-DX4020G if DX4020 / ITS-DX4020G is programmed.
Restore:
Communication with DX4020 / ITS - DX4020G is normal and fault is reset.
Supervise:
1.
2.
3.
–
Condition:
No communication with DX3010 if DX3010 is programmed.
Restore:
2014.4 | 01 | F.01U.267.112
Network / IP Module 1 Failure
Report the DX4020 / ITS - DX4020G fault to configured destination on address 124 when
the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off, when there is no other system fault.
Output Expansion Module Failure
–
Both addresses 0144
and 0145 are set to 0
–
Extension system is used
in the telephone network
–
The telephone network
support ADSL as well
–
The zone silent alarm is
enabled
–
The transmission format
of the receiver is
programmed to 0 = not
used
–
The parameters of ITS-
DX4020-G are not
properly set.
Installation Guide
AMAX panel 4000 / AMAX panel 4000
–
Program the address
0144 to a number from 1
to 15. Program the
address 0145 to 1
–
Add dial delay in
programming
–
Connect the system after
the ADSL filter
–
Disable the zone silent
alarm
–
Program the
transmission format of
the receiver to 1 or 3
–
Recommend to set the
parameter ACK TIMEOUT
of ITS-DX4020-G to the
maximum (600) and set
TRANSMIT BUFFER LIFE
TIME to the maximum
(120)
Bosch Sicherheitssysteme GmbH
EN