CC408 | Quick Reference Guide | 3.
3.10.14
System Status – Access Denied
(Code Retry)
356 to 358
Location
Code retry limit
(0 = unlimited)
Tens digit
Units digit
3.10.15

System Status Reporting Options

359
Location
0
No Codepad Alarm Reports allowed
1
Report to Receiver 1
2
Report to Receiver 2
4
Report to both Receiver 1 and Receiver 2
8
Report to Receiver 2 only if Receiver 1 fails
3.10.16

Test Report Time (Automatic)

360 to 366
Location
Hour of day (tens digit)
Hour of day (units digit)
Minute of day (tens digit)
Minute of day (units digit)
Test Report (tens digit)
Test Report (units digit)
Repeat interval in days
3.10.17

Test Reporting Dialler Options

Location
367
0
No Codepad Alarm Reports allowed
1
Report to Receiver 1
2
Report to Receiver 2
4
Report to both Receiver 1 and Receiver 2
8
Report to Receiver 2 only if Receiver 1 fails
3.11

Outputs Programming

3.11.1

Outputs

368 to 397
Location
Output 1 (Default = Horn speaker)
Event Code
Event Code
Time Base
Time Base Multiplier
Time Base Multiplier
Output 2 (Default = Fire alarm with verification)
Event Code
Event Code
Time Base
Time Base Multiplier
Time Base Multiplier
Bosch Security Systems | 6/04 | 4998152468B
Programming Parameters
Location
Default
356
6
357
7
358
12
Location
Default
360
0
361
0
362
0
363
0
364
7
365
1
366
0
Location
Default
368
1
369
14
Polarity
370
0
371
0
372
0
373
0
374
2
375
7
Polarity
376
10
377
2
378
1
379
5
3.11.1
continued
Location
368 to 397
Strobe Output
(Default = Strobe – reset after 8 hours)
Event Code
Event Code
Polarity
Time Base
Time Base Multiplier
Time Base Multiplier
Relay Output (Default = Sirens running)
Event Code
Event Code
Polarity
Time Base
Time Base Multiplier
Time Base Multiplier
Codepad Buzzer
(Default = Entry/exit warning plus day alarm)
Event Code
Event Code
Polarity
Time Base
Time Base Multiplier
Time Base Multiplier
3.11.2

Event Codes

Event
Description
Code
0
0
EDMSAT – satellite siren (Output 1 only)
0
1
System armed
0
2
System disarmed
0
3
Armed in STAY Mode
0
4
Armed in AWAY Mode
0
5
Pre-arming alert
0
6
Exit warning (all zones sealed) and entry
warning
0
7
Exit warning
0
8
Exit warning finished
0
9
Kiss-off after end of exit time
0
10
Reserved
0
11
Entry warning
0
12
Entry warning and day alarm resetting
0
13
Exit warning and entry warning and day
alarm resetting
0
14
Day alarm resetting
0
15
Day alarm latching
1
0
Day alarm enabled
1
1
Telephone line fail
1
2
Kiss-off received
1
3
Fuse fail
1
4
AC fail
1
5
Low battery
1
6
Horn speaker fail
1
7
Sensor watch alarm
1
8
Codepad medical alarm
1
9
Codepad fire alarm
EN | 14
Location
Default
380
2
381
0
382
6
383
4
384
0
385
8
386
1
387
15
388
1
389
0
390
0
391
0
392
0
393
13
394
2
395
1
396
0
397
1

Hide quick links: