88
en | Configuration
Figure 8.13: Link-Direct Connect
When connected to the AMAX panel, button label changes to "Disconnect".
8.2.2

Modem Connection

Telephone Remote Connection
The telephone remote connection function allows establishing a connection from the remote
PC to the AMAX panel through telephone network.
1.
2.
2014.4 | 01 | F.01U.267.112
Number of rings (address 0144), callback telephone number (address 0146 - 0161), and
telephone remote connection enabled (address 0145) are set on the AMAX panel.
Run RPS on the remote PC and set relevant parameters in relevant operating interfaces.
Go to "File" and click "Communication Settings" to set parameters related to modem in
the communication Settings tab page, then click "Save"