142
en | Troubleshooting
3.
RF Receiver 1 Fault
Condition:
The receiver is abnormal (e.g., RF micro is removed / hold RF micro in reset / ...) if wireless
module is enabled.
Restore:
Communication with receiver is normal, wireless module is enabled, and fault is reset.
Supervise:
1.
2.
3.
RF Receiver 1 Missing
Condition:
1.
2.
Restore:
Communication with receiver is normal, wireless module is enable, and fault is reset.
Supervise:
1.
2.
3.
RF Receiver 1 Jammed
Condition:
Much disturb signal around the receiver, if wireless module is enable.
Restore:
No much disturb signal around the receiver, wireless module is enable, and fault is reset.
Supervise:
1.
2.
3.
RF Sensor Missing
Condition:
If any one wireless zone have no status report to receiver in the RF supervision interval and
wireless module is enable.
Restore:
All wireless zones have status report to receiver in the RF supervision interval and wireless
module is enabled and fault is reset.
Supervise:
1.
2.
2014.4 | 01 | F.01U.267.112
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off, when there is no other system fault.
RF Receiver Failure
Report the receiver fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off, when there is no other system fault.
No communication with receiver if wireless module is enable.
Any RF zone, or repeater, or keyfob is configured, but the wireless module is disable.
Report the receiver missing fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
Report the receiver jam fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
RF Sensor Failure
Report the wireless zone missing fault to configured destination when the fault is
detected.
Slow flash FAULT indicator (refer to Keypad Indicators for the detailed description).