AMAX 2100 / 3000 / 4000
en
Quick Start Manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch AMAX 2100

  • Page 1 AMAX 2100 / 3000 / 4000 Quick Start Manual...
  • Page 3: Table Of Contents

    AMAX 2100 / 3000 / 4000 Table of Contents | en Table of contents Graphics Safety Short information Connecting Modules and Devices Programming and Operating the AMAX System Option: Changing Menu Language Accessing the Menus Menu Navigation Programming the AMAX System via Keypad 5.4.1...
  • Page 4: Graphics

    | Graphics AMAX 2100 / 3000 / 4000 Graphics Figure 1.1: Wiring diagram for AMAX panel 2100 / 3000 2014.11 | 02 | F.01U.309.297 Quick Start Manual Bosch Sicherheitsysteme GmbH...
  • Page 5 AMAX 2100 / 3000 / 4000 Graphics | en AUX 1: < 900mA AUX 2: < 900mA AUX1 AUX2 AUX2 AUX1 RING +12V +12V 18VAC@50VA Keypads: IUI-AMAX4-TEXT Battery IUI-SOL-TEXT 230V ~50Hz 12V 7Ah IUI-AMAX3-LED16 230mA 12V < 18Ah IUI-AMAX3-LED8 Fuse 1 A 5-16 Inst.
  • Page 6: Safety

    | Safety AMAX 2100 / 3000 / 4000 Safety Danger! Electricity Injuries due to electricity are possible if the system is not operated correctly or if the system is opened or modified not accordingly to this manual. – Disconnect all Telecommunication Network Connectors before switching off the power.
  • Page 7 AMAX 2100 / 3000 / 4000 Safety | en – Under normal conditions of use, replace the battery every 3-5 years. – Recycle the battery after replacement according to local regulations. Caution! Installation Damage or malfunction of the system is possible if the system is not mounted and installed correctly.
  • Page 8: Short Information

    | Short information AMAX 2100 / 3000 / 4000 Short information This Quick Start Guide contains information on how to get the system into operation easily and quickly. The guide describes the main steps required for basic system installation and setup of an AMAX panel together with one IUI-AMAX4-TEXT keypad and one RFRC-OPT RADION receiver.
  • Page 9: Connecting Modules And Devices

    Connecting Modules and Devices | en Connecting Modules and Devices The AMAX panel provides BOSCH option bus 1 and option bus 2 (only for AMAX 4000) to connect modules and devices. Each module can be connected to each bus. A maximum of 14 modules (8 keypads) can be connected to each bus.
  • Page 10: Programming And Operating The Amax System

    | Programming and Operating the AMAX System AMAX 2100 / 3000 / 4000 Programming and Operating the AMAX System The AMAX system can be programmed and operated with menus by using keypads and/or the A-Link Plus remote programming software on a PC.
  • Page 11: Programming The Amax System Via Keypad

    AMAX 2100 / 3000 / 4000 Programming and Operating the AMAX System | en Confirming the Input Press [#] to confirm the input. Switching between Settings Press and hold [*] for 3 seconds to switch between settings. Operating a Menu Operate according to the menu prompt.
  • Page 12: Enabling The Rf Receiver For Wireless Communication

    | Programming and Operating the AMAX System AMAX 2100 / 3000 / 4000 The system displays the next menu item: ZONE IN AREA. There is no need to proceed to the following menu items for deleting a zone. Press [–] four times to get to the EXIT PROG. +SAVE menu.
  • Page 13: Programming The Amax Sytem Via Pc And Usb

    The installation creates an additional COM device on the PC. 5.5.3 Starting the Programming Software Select Start – All Programs – Bosch Security Systems – A-Link Plus – A-Link Plus vn.n.n. n.n.n = current program version Double-click the A-Link Plus vn.n.n shortcut on your computer desktop.
  • Page 14: Setting The Com Port

    | Programming and Operating the AMAX System AMAX 2100 / 3000 / 4000 5.5.4 Setting the COM Port The COM port that has been assigned to the additional COM device (here COM4) has to be set in the A-Link Plus program.
  • Page 15 AMAX 2100 / 3000 / 4000 Programming and Operating the AMAX System | en Figure 5.2: Communication Setting – Selecting the direct link port Bosch Sicherheitsysteme GmbH Quick Start Manual 2014.11 | 02 | F.01U.309.297...
  • Page 16: Option: Creating A New Customer

    | Programming and Operating the AMAX System AMAX 2100 / 3000 / 4000 5.5.5 Option: Creating a New Customer If necessary, create a new customer. Select Customer – New Customer from the menu bar. The Customer Information index sheet opens.
  • Page 17: Configuring The Control Panel

    AMAX 2100 / 3000 / 4000 Programming and Operating the AMAX System | en 5.5.6 Configuring the Control Panel Select Customer – Open Customer from the menu bar of the A-link Plus program. The Customer Information dialog opens. Select the Control Panel Configuration index sheet.
  • Page 18 | Programming and Operating the AMAX System AMAX 2100 / 3000 / 4000 Figure 5.5: AMAX panel configuration – subscriber number Select the item Code manager in the same index sheet. Make sure that the value for the parameter Installer code is the same as currently programmed in the AMAX panel.
  • Page 19 AMAX 2100 / 3000 / 4000 Programming and Operating the AMAX System | en Figure 5.6: AMAX panel configuration – installer code Bosch Sicherheitsysteme GmbH Quick Start Manual 2014.11 | 02 | F.01U.309.297...
  • Page 20: Establishing A Direct Connection

    | Programming and Operating the AMAX System AMAX 2100 / 3000 / 4000 5.5.7 Establishing a Direct Connection Select the Link index sheet to establish a connection between the A-Link Plus program and the AMAX panel. Figure 5.7: Link – Selecting Direct Connect Select Direct Connect as communication model.
  • Page 21: Menu Programming

    AMAX 2100 / 3000 / 4000 Programming and Operating the AMAX System | en Menu Programming The following graphics show an overview of the programming menu structure displayed on a text keypad. Figure 5.8: Communications and Reporting Manager Bosch Sicherheitsysteme GmbH Quick Start Manual 2014.11 | 02 | F.01U.309.297...
  • Page 22 | Programming and Operating the AMAX System AMAX 2100 / 3000 / 4000 Figure 5.9: Communications and Reporting Manager (continued) 2014.11 | 02 | F.01U.309.297 Quick Start Manual Bosch Sicherheitsysteme GmbH...
  • Page 23 AMAX 2100 / 3000 / 4000 Programming and Operating the AMAX System | en Figure 5.10: Code Manager Bosch Sicherheitsysteme GmbH Quick Start Manual 2014.11 | 02 | F.01U.309.297...
  • Page 24 | Programming and Operating the AMAX System AMAX 2100 / 3000 / 4000 Figure 5.11: Zone Manager 2014.11 | 02 | F.01U.309.297 Quick Start Manual Bosch Sicherheitsysteme GmbH...
  • Page 25 AMAX 2100 / 3000 / 4000 Programming and Operating the AMAX System | en Figure 5.12: Zone Manager (continued) Bosch Sicherheitsysteme GmbH Quick Start Manual 2014.11 | 02 | F.01U.309.297...
  • Page 26 | Programming and Operating the AMAX System AMAX 2100 / 3000 / 4000 Figure 5.13: Keypad and Area Manager 2014.11 | 02 | F.01U.309.297 Quick Start Manual Bosch Sicherheitsysteme GmbH...
  • Page 27 AMAX 2100 / 3000 / 4000 Programming and Operating the AMAX System | en Figure 5.14: System Manager Bosch Sicherheitsysteme GmbH Quick Start Manual 2014.11 | 02 | F.01U.309.297...
  • Page 28 | Programming and Operating the AMAX System AMAX 2100 / 3000 / 4000 Figure 5.15: Output Manager 2014.11 | 02 | F.01U.309.297 Quick Start Manual Bosch Sicherheitsysteme GmbH...
  • Page 29 AMAX 2100 / 3000 / 4000 Programming and Operating the AMAX System | en Figure 5.16: RF Manager Bosch Sicherheitsysteme GmbH Quick Start Manual 2014.11 | 02 | F.01U.309.297...
  • Page 30 | Programming and Operating the AMAX System AMAX 2100 / 3000 / 4000 Figure 5.17: Address and Key Programming 2014.11 | 02 | F.01U.309.297 Quick Start Manual Bosch Sicherheitsysteme GmbH...
  • Page 31: Technical Data

    AMAX 2100 / 3000 / 4000 Technical Data | en Technical Data Panel AMAX2100 AMAX3000 AMAX4000 Enclosure: Dimensions 260 x 280 x 83.5mm (L x W x H) 375 x 322 x 88 mm(L x W x (HxWxD): Weight: 1950g...
  • Page 32 | Technical Data AMAX 2100 / 3000 / 4000 Pin Code 1000000 variations: Keypads: DX 3010: B 426, or DX 4020, or DX4020G (only DX2010: DX 4010: RF Receiver: RF Repeater: DSRF = 0, Radion = 8 RF Sensors:...
  • Page 33 AMAX 2100 / 3000 / 4000 Technical Data | en Aux 1 / 2 (+12V/ – Nominal Output Voltage under AC line input: 13,8 VDC +3% / -5% GND) Output: – Vpp (max) 675mV – Output Voltage Range under AC line –...
  • Page 34 | Technical Data AMAX 2100 / 3000 / 4000 Certification: Europe EN 50130-4 (6/2011) EN 55022 (5/2008) EN 60950-1:2006 + A11:2009 EN 50131-3 grade 2 Environmental Class 2 France AFNOR NF a2P 1223400001A0 Environmental Class 1 Germany Home IUI-AMAX3-LED16 (16 Zone LED Keypad)
  • Page 35 AMAX 2100 / 3000 / 4000 Technical Data | en EN 50131-3 grade 2 Environmental Class 2 France AFNOR NF a2P 1223400001A0 Environmental Class 1 Germany Home Bosch Sicherheitsysteme GmbH Quick Start Manual 2014.11 | 02 | F.01U.309.297...
  • Page 38 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2014...