AMAX panel 4000 / AMAX panel 4000
EN
1 COM+REPORT MANAG
Figure 8.1: Com+Report
Bosch Sicherheitssysteme GmbH
RECEIVER SETTING
INPUT RECEIVER No.
PHONE/IP PORT No.
SUBSCRIBER ID No.
FORMAT
NETWORK ANTIREPLAY
ACK WAIT TIME: sec
NETW. POLLING: min
REPORT SETTING
ZONE RESTORE REP.
AWAY ARM/DI REPORT
STAY ARM/DI REPORT
SYSTEM STATUS REP.
PANIC ALARM REPORT
FIRE ALARM REPORT
MEDICAL AL. REPORT
AUTOM. TEST REPORT
REPORT EXP. TIME:m
REP DELAY ENTRY T.
TEST REPORT DURAT.
TEST RPT INTERV: h
TEST REPORT: hour
TEST REPORT: min
DUAL IP
DUAL IP SETTING
REMOTE ACCESS
REM. ACCESS ARMED
REMOTE PROGRAMMING
RPC IP/ PORT/ POLL
RPC IP ADDRESS
RPC PORT
5 DIGIT!
RPC POLL: 1-15h
CALLBACK/ DOMESTIC
CALLBACK SETTING
CALLBACK EN/DISAB.
CALLBACK/DOMEST No
DOMESTIC CALL
DOMESTIC No
DOMESTIC PHONE No.
CALLBACK PHONE No
CHG CALLBACK No.
RING TIMES
RING TIMES
1 - 4
_ _ _ _ _ _ _ _ _ _ _ _ _ _
192 168 012 005 07700
000000
1 = CID 2 = SIA 3 = Connetix IP
0 = disabled 1 = enabled
05 - 99 seconds
001 - 999 minutes
00 = No Report
01 = Receiver 1
02 = Receiver 2
03 = Receiver 3
04 = Receiver 1
05 = Receiver 1, 2, 3 and 4
06 = Receiver 1 (2, 3 and 4 for backup)
07 = Rec. 1 (2 for backup) and Rec. 3 (4 for backup)
000 = No time limit 001 - 255 = 1 - 255 minutes
0 = No Delay 1 - Delay (30sec)
00 = Do not use timing report 01 - 99 = 1 - 99 hours
00 - 23 hours Others = Do not use real-time report
00 - 59 minutes Others = Do not use real-time report
0 = 1 IP module 1 = 2 IP modules
0 = disabled 1 = enabled
0 = disabled 1 = enabled
000 000 000 000 (12 Digits!)
00000 (5 Digits!)
1 - 15h
0 = disabled 1 = enabled
(1-4)
1 - 4
_ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _
0
= Panel does not answer
1 - 13 = Number of rings until the control panel responds
14
= Call the control panel and allow the phone to ring no more than twice and hang
up. Wait a minimum of 8 sec and call the control panel again. The control panel
answers on the first ring.
15
= Call the control panel and allow the phone to ring no more than four times and then
hang up. If you call again within 45 sec, the control panel answers the call on the
first ring.
Installation Guide
Configuration | en
Telephone No. </= 17 Digits
IP = 12 Digits! + Port = 5 Digits!
0 - 9 B - E
SSF=0
Module 1 = Receiver 1+2
Module 2 = Receiver 3+4
Domestic Telephone No. </= 17 Digits
Callback Telephone No. </= 17 Digits
2014.4 | 01 | F.01U.267.112
77
default
[15]
[0]
[1]
EN=1
[1]
[05]
[1]
[0]
EN = 1/5/6/7
[6]
EN = 1/5/6/7
[6]
EN = 1/5/6/7
[6]
[0]
[0]
[0]
EN = 1/5/6/7
[6]
EN=0
[000]
EN=1
[1]
EN=1-24
[24]
[99]
[99]
[1]
[1]
[1]
[15]
[15]
[15]
[0]
[15]
[15]
[14]