Maintenance

11.1

Firmware Upgrade with the ICP-EZRU2 Upgrade Key

Use firmware upgrade key (green) to upgrade firmware of the AMAX panel.
Procedure:
1.
2.
3.
4.
2014.4 | 01 | F.01U.267.112
Power OFF AMAX panel. Also remove battery. Unplug USB cable, if plugged.
Connect the programming key to the plug on top of the printed circuit board (PCB) of the
AMAX panel. Please note that the direction of the programming key should be consistent
with the direction marked on the PCB.
Power ON AMAX panel. Observe LED of upgrade key flickers during upgrade is sent to
AMAX panel. This takes about one minute. When upgrade is terminated, LED blinks
slowly.
Remove upgrade key