58
en | Settings
2.
3.
If the zone is programmed to disable 24-hour zone tamper, the wiring method for single-
terminal resistor is required. If the zone detests alarm, the zone will process according to
specified zone type.
Zone Status Reporting
The AMAX panel reports the zone status according to the specified path, including alarm, zone
fault, zone bypass and zone tamper alarm.
Zone Chime Mode
The system will support the chime mode.
The process is as follows:
Zone Pulse count
The system will support the pulse count mode.
The process is as follows:
The process is as follows:
Domestic no.
The system will support the domestic call mode.
The process is as follows:
Cross Zone
The cross zone option works as follows:
Prerequisites:
When one of these zones is triggered for more than 20 seconds, an alarm is created.
When one of these zones (the first zone) is triggered for a shorter time than 20 seconds, the
cross zone timer starts, no alarm is created at this time
2014.4 | 01 | F.01U.267.112
If the zone detects that the 24-hour tamper is triggered, the zone tamper alarm will be
processed the same as 24-hour zone.
If the zone detests zone alarm, the zone will process according to specified zone type.
If the chime mode is used and a zone is triggered the keypad buzzer will sound for 1
second (only in disarmed status)
pulse count duration time must be configured (Refer to chapter 9.1 Communication and
Report Settings)
pulse count for a zone can be set to a value between 1 and 9 (0 = disabled)
an alarm is only created, if the zone is triggered as many times as the value "pulse count"
within the time "count duration"
If the domestic call mode is configured for a zone and an alarm from this zone is created
the alarm will be reported to the destination(s) configured and needs acknowledgement
At least two zones in the same area have option Cross Zone enabled
System option Cross Zone Timer is set to a value higher than 0
When no more zones (with cross zone option) are triggered within the cross zone time,
no alarm is created
When the first zone is triggered twice or more within the cross zone time, no alarm is
created
When a second zone or further zones (with cross zone option) is / are triggered within
the cross zone time, then an alarm is created for all triggered zones
When the first zone or one of the other zones (with cross zone option) is / are triggered
twice or more after cross zone time is expired, the timer restarts
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Bosch Sicherheitssysteme GmbH
EN