To program the IP Address and port:
Use no punctuation in IP address. If any unit of IP address is less than 3 digits, use 0 to fulfill
the data in the higher bits. The remaining 5 digits will program the port. Port number ranges
from 0-65535. If port number is less than 5 digits, use 0 to fulfill the data.
Example
To program the IP Address 10.16.1.222:80 as the IP Address of Receiver 1, enter the following
sequence into Address 000 - 016:
[0 1 0 0 1 6 0 0 1 2 2 2 0 0 0 8 0]
Notice!
Programming option anti-replay, acknowledge wait time, and pulse interval time are only used
in Conettix IP.
Telephone number for Receiver 1 - 4/IP Address and Port
When the corresponding data format for above programming address is a network
communication format, it is explained as an IP Address, and Port. For a non network format, it
is explained as telephone number.
AMAX panel contacts the telephone number / IP Address of the central monitoring station in
order to transmit a report. If the contact is successful, the relevant information is transmitted,
and the communicator returns to Standby Mode.
Contact your monitoring station for the correct telephone number / IP Address before you
program these addresses.
Receiver Subscriber ID Number
Receiver 1 - 4 Subscriber ID Number
The Subscriber ID Number is transmitted to identify the calling AMAX panel. Digits from 0 to 9
and letters from B to F are only valid. Enter the Subscriber ID Number in the six addresses
provided for each destination. If a Subscriber ID Number is less than 6 digits, use 0 to full fill
the data in the higher bits.
Example
Program Subscriber ID Number as 4729 in six addresses: [0 0 4 7 2 9]
Receiver Transmission Format
Transmission Format
Receiver 1 - 4 Transmission Format
You can select the transmission format with Address options to specify how to transmit the
information to the base station receiver. If Contact ID or SIA format is selected, the
information is transmitted by telephone line; if Bosch Network is selected, then it is
connected with B426 / DX4020 or ITS-DX4020G GPRS. Transmission format is defaulted as
Contact ID.
Transmission Formats (Contact ID, SIA, Conettix IP)
The AMAX panel 4000 provides three kinds of transmission formats, Contact ID, SIA, and
Conettix IP format for its dialing and communication features. Program the transmission
format for Receiver 1, 2, 3, and 4 separately in Address 023, Address 053, Address 083, and
Address 113 (refer to Transmission Format). The AMAX panel is set at the factory to report in
the Contact ID Format.