U252/Set Dest - Kyocera ECOSYS M3040dn Service Manual

Hide thumbs Also See for ECOSYS M3040dn:
Table of Contents

Advertisement

U252
Set Dest
Description
Switches the operations and screens of the machine according to the destination.
Purpose
To be executed after initializing the backup RAM, in order to return the setting to the value before
replacement or initialization.
Method
1. Press the start key.
2. Select the destination.
Display
(No Action)
Inch
Europe Metric
Asia Pacific
Australia
China
Korea
3. Press the start key.
4. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
* : An error code is displayed in case of an initialization error.
When errors occurred, turn main power switch off then on, and execute initialization using
maintenance item U252.
Error codes
Display
0001
0002
0020
0040
-
Inch (North America) specifications.
Metric (Europe) specifications.
Metric (Asia Pacific) specifications.
Australia specifications.
China specifications.
Korea specifications.
Controller (Entity Error)
Controller (Counter Error)
Engine
Scanner
1-3-44
2NM/2NX/2NY/2NZ/2P0/2P6-1
Description
Description