U070
Adj DP Motor
Description
Adjusts the DP original scanning speed.
Purpose
Make the adjustment if the magnification is incorrect in the auxiliary scanning direction when the
DP is used.
Adjustment
1. Press the start key.
2. Press the system menu key.
3. Place an original on the DP and press the start key to make a test copy.
4. Press the system menu key.
5. Select [Convey Speed].
Display
Convey Speed
6. Change the setting value using the cursor right/left keys or numeric keys.
For copy example 1, increase the value. For copy example 2, decrease the value.
Increasing the value makes the image longer, while decreasing the value makes the
image?shorter.
7. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Sub scanning direction. (Front)
Original
Setting
range
-25 to 25
Copy
Copy
example 2
example 1
Figure 1-3-9
1-3-32
2NM/2NX/2NY/2NZ/2P0/2P6-1
Initial
Change in
setting
value per step
0
0.1 %