(1-1) Detaching and refitting the exposure lamp

Procedure
1. Slide the right operation lid and the left
operation lid.
2. Remove the their lids.
3. Remove the operation panel cover.
4. Replace it to the operation panel sheet
of the corresponding language.
Left
operation lid
Left operation
panel cover
Left operation
panel sheet
1-5-16
2NM/2NX/2NY/2NZ/2P0/2P6-1
Right
operation lid
Figure 1-5-23
Left operation
panel cover
Left operation
panel sheet
Operation panel assembly