Detaching And Refitting The Main Driving Motor Unit - Kyocera ECOSYS M3040dn Service Manual

Hide thumbs Also See for ECOSYS M3040dn:
Table of Contents

Advertisement

1-5-12 Othes

(1) Detaching and refitting the main driving motor unit

Procedure
1. Remove right middle cover.
(See page 1-5-90)
2. Remove right lower cover.
(See Page 1-5-91)
3. Pull the connector out from the motor
and then release the wires from wire
holder.
4. Remove three screws and then remove
the main driving motor unit.
5. Check or replace the main driving motor
unit and refit all the removed parts.
Wire holders
Connectors
Wires
(50/60 ppm model)
Wire holders
Connector
Wires
(40 ppm model)
1-5-94
2NM/2NX/2NY/2NZ/2P0/2P6-1
Main drive
motor unit
Figure 1-5-161
Main drive
motor unit
Figure 1-5-162
Screws
Screws

Hide quick links: