(2) Detaching and refitting the inlet cover and the interface slot cover

Procedure
1. Open the rear cover.
2. Remove the Upper interface cover and
then lower interface cover.
3. Remove the inlet cover.

(3) Detaching and refitting the right stay cover

Procedure
1. Remove the upper interface cover.
2. Release two hooks using a flat screw
driver and remove the right stay cover.
Upper
interface cover
Lower
interface cover
Inlet cover
Upper
interface cover
1-5-85
2NM/2NX/2NY/2NZ/2P0/2P6
Hook
Rear cover
Figure 1-5-143
Right stay cover
Hooks
Flat screw driver
Figure 1-5-144