4.2 CONNECTING THE KX-TVP50 WITH THE PANASONIC KX-TA series
Screen output:
This message is shown when the digital (APT) connection between the VPS and
telephone system cannot be established.
Possible causes of the message: "APT Interface Connection is not Established"
The PBX is not a KX-TA series
system. Since the default PBX type for
the KX-TVP50 is to KX-TA series at
the factory, this message will always
appear when connecting to another
type of PBX.
The cabling between the PBX
extension ports and the VPS is not 4-
wire or is improperly connected.
The PBX is a KX-TA series but does
not have the proper level of software
required to support APT Integration.
The PBX is not programmed properly
to support APT Integration.
10.
Start up completed.
a)
The Power Indicator light stops blinking when the start-up has been successful. (The
delay varies according to the system's condition.)
b)
"**ON LINE MODE**" is displayed.
c)
System prompt [>] is displayed on the screen. To enter system administration, Press
ENTER. All parameters can be set through the menu-driven program.
11.
Go to the System Administration Top Menu. Type [5] and Press ENTER, or Type [3] then
QSET and Press ENTER for Quick Setup and follow the Auto Configuration Instructions.
62
Active COs: 1 2
APT Interface Connection is not Established
** OFF LINE MODE **
Cause
INTEGRATING THE VPS WITH THE PANASONIC KX-TA ANALOGUE PBX AND KX-TD DIGITAL PBX
Table 15
Action
Change the PBX type by using
Quick Setup (see Section 5).
Confirm the cabling is
connected as described in
Section 2 INSTALLATION.
Consult your dealer or use
Inband Integration under
hardware settings.
Do required integration
programming as described in
this chapter.

Hide quick links: